background image

mega macs 56 Bike

Working with the Device

Symbols

7.1.2

Symbols in the Header

S

Syym

mbboollss

D

Deessiiggnnaattiioonn

Vehicle data

This menu contains the data of the currently selected vehicle.

User

Here you can click the symbol to change the user or double-click

to enter a new

user name.

Help

Select the menus

>Assistance in selection<

and

>User Manual<

.

>Assistance in selection<

Indication of the active assistance for the different icons and the drop-down menu

Black symbol: Help function is inactive

Green symbol: Help function is active

>User Manual<

Calling up the complete manual

Shopping cart

The spare parts booked for order are indicated with the following information:

Quantity

Component name

Manufacturer

Item number

The shopping cart symbol is dark if there are spare parts in the cart.

Order network

This network is used for data exchange between device and order network.

Mail box

The incoming e-mails and help calls are stored here. The symbols indicate an
incoming e-mail or help call:

Envelope symbol: No new e-mails

Envelope symbol with exclamation mark: At least one new e-mail

Call up the corresponding list using the symbol.

Battery state of charge

The battery state of charge is indicated here.

Green symbol: Battery is fully charged.

Symbol flashing green-white: Battery is being charged.

Symbol partly red: Battery must be charged.

Printer

Printer is ready for operation

Black symbol: Printer is ready

Symbol flashes green-black: Print job is in progress

Red symbol: Connecting error between device and PC.

47

Summary of Contents for mega macs 56

Page 1: ... HBMM56V5400EN0818S1 460 990 37 08 18 User Manual en mega macs 56 Bike Original User Manual ...

Page 2: ...14 2 2 Non Liability 14 2 2 1 Software 14 2 2 1 1 Safety Relevant Software Modifications 14 2 2 1 2 Performing Safety Relevant Software Modifications 14 2 2 1 3 Prohibition of Safety Relevant Software Modifications 14 2 2 1 4 Waiver of the Use of Safety Relevant Software Modifications 15 2 2 1 5 Offer for All 15 2 2 2 Non Liability 15 2 2 2 1 Data and Information 15 2 2 2 2 Burden of Proof on the ...

Page 3: ...conditions for an Update 27 6 2 2 Calling Up System Information 27 6 2 3 Setting the Language 27 6 2 4 Starting the System Update 27 6 2 5 Calling Up DT VCI Information 28 6 2 6 DT VCI Update 28 6 2 6 1 Starting a DT VCI Update 28 6 2 7 Module Update 29 6 2 7 1 Starting the Module Update 29 6 3 Configuring the Interfaces 29 6 3 1 Configuring the Printer 30 6 3 1 1 Printing via USB Port 30 6 3 1 2 ...

Page 4: ...tomatic Car History Transfer 38 6 6 2 2 Manual Parameter Management 39 6 6 2 3 Sending the Car History 39 6 6 2 4 Parameter Management 39 6 6 2 5 Displaying Error Logs 40 6 6 3 Configuring Other Matters 40 6 6 3 1 Setting the Demo Mode 40 6 6 3 2 Setting Tips 40 6 6 3 3 Automatic E mail Actualization 41 6 6 3 4 Configuring Order Management 41 6 6 3 5 Performing a Factory Reset 41 6 6 3 6 Screensho...

Page 5: ...rch 60 7 2 1 1 Country Specific Search of Vehicle 60 7 2 1 2 Searching a Vehicle by Registration Number 61 7 3 OBD diagnostics 62 7 3 1 Performing an OBD Diagnostics Quick Start 62 7 4 Diagnostics 62 7 4 1 Preparing Vehicle Diagnostics 63 7 4 2 Trouble codes 64 7 4 2 1 Reading Out Trouble Codes 64 7 4 2 2 Deleting Trouble Codes in Vehicle System 65 7 4 2 3 Global Check Reading Trouble Codes 65 7 4...

Page 6: ... 3 1 Manual Setting of Measuring Ranges 86 8 1 3 2 Automatic Setting of Measuring Ranges 87 8 1 3 3 Deactivating Automatic Measuring Range Adaptation for Resistance Measurement 87 8 1 4 Configuring the Trigger 87 8 1 4 1 Setting the Trigger Position 87 8 1 4 2 Setting the Trigger Mode 88 8 1 4 3 Setting the Trigger Edge 88 8 1 4 4 Setting the Trigger Level 89 8 1 5 Other Functions 89 8 1 5 1 Calib...

Page 7: ...lculations 93 9 3 1 Calling Up Calculations 93 10 General Information 95 10 1 Troubleshooting 95 10 2 Care and Maintenance 95 10 2 1 Replacing the Battery 96 10 3 Disposal 96 10 4 Technical data of the mega macs 56 Bike 97 10 4 1 General Data 97 10 4 2 DT VCI 98 10 4 3 Measurement Module 99 7 ...

Page 8: ... The device shall be used exclusively by a qualified person Information and knowledge included this training is not explained in this user manual The manufacturer reserves the right to modify this manual and the device itself without prior notice We therefore recommend checking it for any updates This manual must accompany the device in case of sale or other transfer This user manual must be kept ...

Page 9: ... label indicates that the product must not be discarded as domestic waste The bar underneath the waste bin indicates whether the product was placed on the market after August 13 2005 Direct current voltage This label indicates a direct current voltage Direct current voltage means that the electrical voltage does not change over a longer period of time Observe user manual This label indicates that ...

Page 10: ... This marking indicates that the user manual the operating instructions must always be read and always be available Direct current voltage This label indicates a direct current voltage Direct current voltage means that the electrical voltage does not change over a longer period of time Fire hazard This label indicates that the object must not be thrown into open fire European Recycling Platform ER...

Page 11: ...event incorrect handling and consequent injuries to the user or damage to the device observe the following Select functions and menus on the touch screen display only with clean fingers Do not use a tool e g screwdriver Only connect original power adapter to the power cord supply voltage 12 15 V Protect the TFT LCD and the device from long periods of exposure to solar radiation Protect the device ...

Page 12: ... of Injury When working on the vehicle there is a risk of injury through rotating parts or rolling of the vehicle Therefore regard the following Prevent the vehicle from rolling Additionally place gear selector lever of AT vehicles to park position Deactivate the start stop system to avoid an inadvertent engine startup Connect the device to the vehicle only when engine is shut down Do not reach in...

Page 13: ...p the service disconnect plug safe or secure the battery master switch against re activation Insulate the battery master switch the plug connections etc with dummy plugs covering caps or insulating tape with the corresponding warning notice Check the de energized state with a voltage tester Even with disconnected high voltage system residual voltage can still be present Ground and short circuit th...

Page 14: ...lso include components in safety related vehicle systems e g airbag or brakes The following notes and instructions also apply to future updates and related software extensions 2 2 1 2 Performing Safety Relevant Software Modifications Work on safety related areas e g the occupant safety system and the brake system is only allowed to be performed if the user has read and accepted this note The user ...

Page 15: ...Non Liability 2 2 2 1 Data and Information The information in the database of the diagnostic program has been compiled based on automotive and importer information Great care was taken to ensure the correctness of the information The Hella Gutmann Solutions GmbH accepts no liability for any mistakes and the resulting consequences This statement also applies to the use of data and information that ...

Page 16: ... Hella Gutmann Solutions GmbH does not accept any liability for any losses in relation to loss of profit goodwill or any other loss including financial loss Hella Gutmann Solutions GmbH accepts no liability for damages or operating trouble resulting from failure to observe the mega macs user manual and the special safety precautions The burden of proof is on the user of the device that he has paid...

Page 17: ...uide 3 1 1 Checking Delivery Contents Please check the delivery contents upon receiving your device so that complaints can be issued immediately regarding any potential damage Proceed as follows to check the delivery contents 1 Open the package supplied and check for completeness based on the delivery slip Should you identify any damage to the package then open the package in the presence of the d...

Page 18: ...suitable for repairing electrical machines and equipment or home electrics Diagnostic devices from other manufacturers will not be supported If the device is used in a way not authorized by Hella Gutmann the safety of the device may be influenced 3 3 Using the Bluetooth Function The terms of use of the Bluetooth function may be restricted or prohibited through law or corresponding legal regulation...

Page 19: ...ice and battery charge connection 4 ON OFF button Switch the device on and off 5 Measurement module MT 56 The module contains a 2 channel oscilloscope for the following measured variables Voltage Current with amp clamp Resistance 6 Oscilloscope 1 connectors Connect a test lead to Scope 1 blue signal black ground 7 ST3 connector Here you can connect an amp clamp 8 Oscilloscope 2 connectors Connect ...

Page 20: ...rface of the PC 3 7 1 Meaning of the Flashing Frequencies S St ta at tu us s d di is sp pl la ay y M Me ea an ni in ng g B Bl lu ue e L LE ED D G Gr re ee en n L LE ED D LED switched off LED switched off Software inactive faulty No voltage present DT VCI faulty LED flashes quickly 1x per sec LED switched off Update failed Update invalid DT VCI faulty LED flashes slowly every 3 sec LED switched off...

Page 21: ...cle provided by Hella Gutmann the device requires a permanent online connection and the installed driver package Hella Gutmann Drivers To keep the connection costs down Hella Gutmann recommends a DSL connection and a flat rate 1 Install the Hella Gutmann Drivers on the office or repair shop PC The driver package Hella Gutmann Drivers program is on the supplied HGS data carrier 2 Connect the device...

Page 22: ...on the device please contact the responsible support staff or the Hella Gutmann Technical Help Line Proceed as follows to switch on the device 1 Briefly push the ON OFF button The GTCs appear 2 Read the GTCs and confirm them at the end of the text The user selection window is displayed The respective user name is saved for all data stored in the Car History This enables quicker identification of t...

Page 23: ... working with the device 5 4 Switching off the Device Proceed as follows to switch off the device NOTE Under normal conditions it is sufficient to switch off the device with For transport and storage the device must be switched off with the ON OFF button so that it cannot be switched on unintentionally 1 Switch off the device with 2 Observe the confirmation prompt 3 Switch off the device with Abor...

Page 24: ... 6 Repeat steps 3 5 for further entries 6 1 2 User Name 6 1 2 1 Entering the User Name Here you can manage the different users The respective user name is saved for all data stored in the Car History This enables quicker identification of the mechanic who performed the repair work if a query is subsequently made Proceed as follows to enter the user name 1 Select Company under Settings in the main ...

Page 25: ...onfirm the confirmation prompt with Password will be deleted 6 1 2 4 Deleting the User Name Proceed as follows to delete the user name 1 Select Company under Settings in the main menu 2 Select User 3 Select the required user name 4 Delete the user name with 5 Observe the confirmation prompt 6 Confirm the confirmation prompt with The user name is deleted 6 1 2 5 Activating the Car History Proceed a...

Page 26: ...e cleared and might possibly not be restored Proceed as follows to set up the password protection 1 Select Company under Settings in the main menu 2 Select User 3 Call up Password management with NOTE The length of the password must not exceed 10 characters 4 Enter a password and confirm by entering it again 5 Observe the warning notice and confirm The device can now be accessed only with the sele...

Page 27: ...ars Here you can find information including the software and hardware version and the device number 6 2 3 Setting the Language Here you can set the language version if the software is multilingual After having set the language the update will be installed in this language Proceed as follows to set the language 1 Select Update under Settings in the main menu 2 Select System 3 Open the list under La...

Page 28: ...e Update the software for the DT VCI here 6 2 6 1 Starting a DT VCI Update NOTICE Insufficient voltage supply System data loss Do not switch off the device and the DT VCI during the update and do not disconnect them from voltage supply Ensure sufficient voltage supply Proceed as follows to start the DT VCI update 1 Select Update under Settings in the main menu 2 Select DT VCI CAUTION Rolling of ve...

Page 29: ...fficient voltage supply Proceed as follows to start the module update 1 Select Update under Settings in the main menu 2 Select the tab for the required module An info window appears Here you can find information on the software and hardware version and the module type 3 Start the module update with 4 Regard the window with infos and instructions 5 Confirm the window with infos and instructions wit...

Page 30: ... mm 11 Confirm your entry with The input will be saved automatically 12 Repeat steps 8 11 for further entries 13 Where necessary activate the check box Blank out company logo to print out results without the company logo of Hella Gutmann This function enables hard copy printouts on printed paper It is now possible to print using the printer on the USB port 6 3 1 2 Printing with Standard PC Printer...

Page 31: ... to connect to the USB ports any printer that supports at least the printer language PCL5 or higher and that has a USB port Proceed as follows to print out results through the expert mode 1 Select Interfaces under Settings in the main menu 2 Select Printer 3 Open a list under Interface with 4 Select Expert mode 6 3 2 Configuring the Bluetooth Adapter Configure the Bluetooth adapter here The integr...

Page 32: ...Deleting the Assignment Here you can disconnect the Bluetooth adapter connection and delete the assignment Proceed as follows to disconnect the Bluetooth adapter connection and delete the assignment 1 Select Interfaces under Settings in the main menu 2 Select the Bluetooth tab 3 Activate the check box to take settings A confirmation prompt appears if WLAN was previously activated in the device 4 O...

Page 33: ...nder IP address mode with A drop down list appears If Determine automatically DHCP is set then the device will automatically search for the IP address This option is set ex works If Determine manually is set you must enter the address of the remote station under mega macs IP address e g 192 168 255 255 7 Select Determine automatically DHCP or Determine manually The selection will be saved automati...

Page 34: ... previously activated in the device 5 Observe the confirmation prompt 6 Confirm the confirmation prompt with 7 Start WLAN diagnostics with An info window appears Here you will find information including the WLAN chip and status as well as the status of the Hella Gutmann Drivers connection 8 Close the info window with 6 3 3 3 Resetting the WLAN Configuration Proceed as follows to reset the WLAN con...

Page 35: ...ose the window with infos and instructions with The device switches off automatically The language setting will be saved automatically 6 Switch on the device with the ON OFF button 7 Confirm the user selection window with The main menu appears 6 4 2 Making Country Settings Make your country settings here The country version contains certain information such as the print format for letters Proceed ...

Page 36: ...me Format Here you can set the time format Proceed as follows to set the time format 1 Select Country under Settings in the main menu 2 Open the list under Time format with 3 Select 24 h or 12 h The selection will be saved automatically 6 4 6 Setting the Date Here you can set the present date Proceed as follows to set the date 1 Select Country under Settings in the main menu 2 Open the drop down l...

Page 37: ... 5 Setting Units Adapt physical units to the prevailing regional metric system here 6 5 1 Assigning Units Proceed as follows to assign regional units to physical sizes 1 Select Units under Settings in the main menu 2 Open a list under the requested unit with 3 Select the requested unit The selection will be saved automatically 6 6 Configuring Miscellaneous Here you can configure settings such as D...

Page 38: ...y management automatic switch off with 4 Select on or off If off is selected the device will remain in stand by mode until the battery is empty If on is selected device will switch off automatically after 10 min The selection will be saved automatically 6 6 2 Configuring the Car History This menu provides the diagnostic results to the present vehicle from the functions Trouble codes Parameters Bas...

Page 39: ...ar History Here you can send the Car History to Hella Gutmann Proceed as follows to send the Car History data 1 Select Miscellaneous under Settings in the main menu 2 Select Car History 3 Send Car History with The Car History is sent to Hella Gutmann 6 6 2 4 Parameter Management NOTE The menu point Parameter management can be done only if Manage parameters manually is set to on With the Parameter ...

Page 40: ...the device shall give predetermined values during the vehicle communication This setting is mainly intended for marketing and sales presentations NOTE In the course of vehicle diagnostics the demo mode must be switched off Otherwise the device will deliver predetermined diagnostic results and no real values Proceed as follows to set the demo mode 1 Select Miscellaneous under Settings in the main m...

Page 41: ...r management with 4 Select on or off Order management is switched off or on The selection will be saved automatically 6 6 3 5 Performing a Factory Reset Here you can reset the device to factory settings The following data and files will be reset to the state of delivery if you do the factory reset Data stored in the Car History Downloaded files such as wiring diagrams or service schedules User dat...

Page 42: ...nn Drivers 1 Select Miscellaneous under Settings in the main menu 2 Select Miscellaneous 3 Send screenshot with A connection is established This may take a few minutes Screenshots are sent to the Hella Gutmann Drivers The message Screenshots successfully sent appears if screenshots have been sent successfully 6 7 Contracts Here you can see the general terms and conditions as well as the licenses a...

Page 43: ...nctions Voltage supply of the device through mains supply and mains cable is ensured DT VCI connected to the device via Bluetooth DT VCI is not connected to the vehicle s diagnostic port 6 8 2 Performing the VCI Plug Test This test serves as a function check for faults in the DT VCI Proceed as follows to perform the test functions 1 Select Test functions under Settings in the main menu 2 Start the...

Page 44: ...d voltage peaks when connecting the DT VCI Danger of destruction of automotive electronics Switch off ignition before connecting the DT VCI to the vehicle 3 Insert the DT VCI into the vehicle s diagnostic connector Both LEDs of the DT VCI flash The DT VCI is ready for operation 4 Start VCI diagnostics Bluetooth with The window Bluetooth diagnostics appears The Bluetooth function is being tested VC...

Page 45: ...following functions Start the selected function Confirm the present entry Confirm your menu selection Cancel Cancel the following functions Active function Input Start Start a function or procedure Delete Delete data or entries Arrow keys Navigate with the cursor in menus or functions Print Print the current window Help Open the user manual and explanations on the individual menus or functions Vir...

Page 46: ...Sy ym mb bo ol ls s D De es si ig gn na at ti io on n Selection window Open a selection window Select all Select all available elements Unselect all Unselect all available elements Zoom in Zoom in the present view Zoom out Zoom out of the present view 46 ...

Page 47: ...he following information Quantity Component name Manufacturer Item number The shopping cart symbol is dark if there are spare parts in the cart Order network This network is used for data exchange between device and order network Mail box The incoming e mails and help calls are stored here The symbols indicate an incoming e mail or help call Envelope symbol No new e mails Envelope symbol with excl...

Page 48: ...and the DT VCI The symbol shows the active connection Black symbol Connection to DT VCI is inactive Green symbol At least 1 connection to the DT VCI is active PC connection status Here you can view the active and inactive interfaces between the device and the PC e g USB Bluetooth WLAN The symbol shows the active interface Black symbol No interface is active Green symbol At least 1 interface is act...

Page 49: ...e Information Diagnostics Here you can find vehicle specific ECU diagnostics e g Trouble code readout Parameter readout Codings Vehicle Information Here you will find information regarding the selected vehicle Car History Measurements The 2 channel oscilloscope is stored here The 2 channel oscilloscope supports the following measured variables Voltage Resistance Current Applications Useful applica...

Page 50: ...ar History here Display Car History files Call up a list of saved diagnostic data records on a certain vehicle Page forward Go one page forward Page back Go one page back Information Here you can call up information regarding the selected vehicle e g Vehicle type Engine displacement Output Engine code Update the Car History Update the list of vehicles in the Car History and the vehicle status here...

Page 51: ...arameters to the selected parameters here Selection to the left Relocate single parameters back to the list of available parameters here Select all Relocate all parameters selected back to the list of available parameters Parameter information Call up detailed information on the selected parameter Parameter selection Return to the parameter list Save parameters Save the automatic recording of the ...

Page 52: ...st data here Next step Call up the next step of the help dialog Next entry Here you can call up the next entry in the Car History Previous step Call up the previous step of the help dialog Previous entry Here you can call up the previous entry in the Car History Add data inquiry or symptom Add another data inquiry or a further symptom to a help call Call for help memory View all the stored helps c...

Page 53: ...ement Save the performed measurement here Settings Make various settings for signal acquisition and the output of values Adjust cursor Open functions for the cursor setting here Cursor position Measuring Signals Cursor settings Trigger Open the functions for the trigger setting The triggering fixes a voltage point of the signal and displays this point always at the same position on the monitor The...

Page 54: ...tart over Start the measurement Change from the display of a stored measurement directly to Oscilloscope 7 1 7 1 Symbols in the Cursor Settings Menu S Sy ym mb bo ol ls s D De es si ig gn na at ti io on n Place the cursor Here you can move the cursor Measuring Signals Use these keys to set the current x and y cursor position as start mark to the signal so that a signal range can be measured afterw...

Page 55: ... Trigger Menu S Sy ym mb bo ol ls s D De es si ig gn na at ti io on n Place the trigger Move the trigger here Set the trigger level Set the trigger level here Trigger settings Perform the following trigger settings Trigger channel Trigger mode Trigger edge Trigger level 55 ...

Page 56: ...w the maximum distance between the upper and lower signal peak of the entire measuring process Frequency View the signal frequency here Period duration View the duration of a signal period here On off ratio Here you can view the percentage signal to noise relation duty cycle of the time the signal is switched on and switched off One signal period is One signal period is 100 This indication mode is...

Page 57: ... value windows to zero position Set the following value windows to zero simultaneously so that only future values will be taken into account Minimum Maximum Peak to peak Auto Set Analyze the incoming signal once and automatically set the ideal measuring range If the measurement signal changes during the ongoing measurement the Auto Set function does not correct the measuring range automatically St...

Page 58: ...u can add a new user the the list of device users The prevailing user name is saved for all data stored in the Car History This enables quicker identification of the mechanic who performed the repair work if a query is subsequently made Start diagnostics Here you can start a connection test of the prevailing interface Find and configure wireless network Search for wireless networks and make the ne...

Page 59: ...pecific keypads from the Available keypads list to the Keypad list Remove keypad from list Here you can remove country specific keypads from the Keypad list 7 1 11 Symbols in the Manual S Sy ym mb bo ol ls s D De es si ig gn na at ti io on n Search for entries Hear you can search for certain words Search for next entry Here you can search for a related entry that corresponds to the entered search ...

Page 60: ...ut The input will be saved automatically Vehicle selection is now ready for Diagnostics and Vehicle data and the data will be stored in the Car history The device will then automatically switch back to the main menu 7 2 1 Vehicle search Here you can search for vehicles in the vehicle database using the following parameters Manufacturer key License plate number 7 2 1 1 Country Specific Search of Ve...

Page 61: ...hicle selection Page 59 7 2 1 2 Searching a Vehicle by Registration Number NOTE Vehicle search by registration number is possible only for the following countries Denmark France type mine Ireland Netherlands Norway Austria national code Sweden Switzerland type approval number Proceed as follows to search for a vehicle according to its registration number 1 Select Vehicle selection in the main menu...

Page 62: ... Start Proceed as follows to perform an OBD diagnostics quick start 1 Select Vehicle selection in the main menu 2 Select i 3 Select OBD diagnostics with 4 Select the requested manufacturer 5 Select the requested fuel type 6 Select the requested system 7 Confirm the selection with 8 Observe the info window 9 Confirm the info window with if appears The diagnostics start 7 4 Diagnostics Here you can ...

Page 63: ... The following ECU functions are possible in the Diagnostics menu Trouble code readout Parameter readout Actuator tests Service reset Basic settings Codings Test function Proceed as follows to prepare vehicle diagnostics 1 Perform steps 1 to 10 as described in the section Vehicle selection Page 59 CAUTION Rolling of vehicle Risk of injury or material damage Proceed as follows before starting 1 Pre...

Page 64: ...3 Regard the window with infos and instructions NOTICE Short circuit and voltage peaks when connecting the DT VCI Danger of destruction of automotive electronics Switch off ignition before connecting the DT VCI to the vehicle 2 Insert the DT VCI into the vehicle s diagnostic connector Both LEDs of the DT VCI flash The DT VCI is ready for operation 3 Select Diagnostics Function Trouble codes NOTE T...

Page 65: ...t trouble codes of a vehicle system Proceed as follows to delete the trouble codes of a vehicle system 1 Perform steps 1 to 13 as described in the section Reading out trouble codes Page 64 NOTE All trouble codes selected will be irrevocably deleted from the ECU memory after the deletion process Therefore always save the read out data read in the Car History 2 Clear the saved trouble codes from the...

Page 66: ...type Functions Assemblies Systems Data 4 Select Global check 5 Call up the Information tab 6 Follow the instructions on the screen 7 Call up the ECU overview with 8 Select further sub categories where necessary The device indicates all ECUs installed in the vehicle The device automatically activates all ECUs Deactivate all ECUs with Activate all ECUs with 9 Activate deactivate the requested ECUs 1...

Page 67: ...e codes will be deleted 7 4 3 Parameters Many of the on board systems supply digital measured values in the form of parameters for fast diagnostics Parameters indicate the present state or nominal and actual values of the components The device displays the parameters alphanumerically and graphically Example 1 The engine temperature can be within a range of 30 C to 120 C If the temperature sensor r...

Page 68: ...ufacturer and vehicle type Functions Assemblies Systems Data 5 Select the requested assembly 6 Regard the warning notice if appears 7 Select the requested system 8 Observe the information and instructions windows 9 Call up the Information tab 10 Follow the instructions on the screen 11 Call up the parameter with 12 Select the OBD plug and system 13 Regard the window with infos and instructions 14 ...

Page 69: ...the present measurement will be removed from the memory and the free capacity is filled with new data 18 Press to cache the records of the selected parameters The recordings are saved in the Car History The parameter readout will start again afterwards 19 Return to the list of parameter selection with 7 4 4 Actuators Use this menu to activate components in electronic systems You are hence able to ...

Page 70: ...NOTE The selection of the following possibilities depends on the selected manufacturer and vehicle type Functions Assemblies Systems Data 5 Select the requested system 6 Select the requested assembly 7 Observe the info window 8 Call up the Information tab 9 Follow the instructions on the screen 10 Start the actuator test with 11 Select the OBD plug and system 12 Regard the window with infos and in...

Page 71: ... the manual service reset 1 Perform steps 1 to 10 as described in the section Vehicle selection Page 59 NOTICE Short circuit and voltage peaks when connecting the DT VCI Danger of destruction of automotive electronics Switch off ignition before connecting the DT VCI to the vehicle 2 Insert the DT VCI into the vehicle s diagnostic connector Both LEDs of the DT VCI flash The DT VCI is ready for oper...

Page 72: ...the vehicle 2 Insert the DT VCI into the vehicle s diagnostic connector Both LEDs of the DT VCI flash The DT VCI is ready for operation 3 Select Diagnostics Function Service reset NOTE The selection of the following possibilities depends on the selected manufacturer and vehicle type Functions Assemblies Systems Data 4 Select the requested system 5 Observe the info window 6 Call up the Information ...

Page 73: ... instructions Proceed as follows to perform the manual basic setting 1 Perform steps 1 to 10 as described in the section Vehicle selection Page 59 CAUTION Rolling of vehicle Risk of injury or material damage Proceed as follows before starting 1 Prevent the vehicle from rolling 2 No gear is engaged 3 Regard the window with infos and instructions NOTICE Short circuit and voltage peaks when connectin...

Page 74: ...ow with infos and instructions Proceed as follows to perform the automatic basic setting 1 Perform steps 1 to 10 as described in the section Vehicle selection Page 59 CAUTION Rolling of vehicle Risk of injury or material damage Proceed as follows before starting 1 Prevent the vehicle from rolling 2 No gear is engaged 3 Regard the window with infos and instructions NOTICE Short circuit and voltage ...

Page 75: ...ith Communication to vehicle is being established Basic settings are made automatically The message Basic setting successfully done appears if the basic setting was successful 7 4 7 Codings Here you can code components and ECUs Codings are necessary if components were replaced or additional functions in an electronic system must be activated 7 4 7 1 Performing Manual Coding Procedures WARNING The ...

Page 76: ...on before connecting the DT VCI to the vehicle 2 Insert the DT VCI into the vehicle s diagnostic connector Both LEDs of the DT VCI flash The DT VCI is ready for operation 3 Select Diagnostics Function Codings NOTE The selection of the following possibilities depends on the selected manufacturer and vehicle type Functions Assemblies Systems Data 4 Select the requested assembly 5 Select the requeste...

Page 77: ...llows before starting 1 Prevent the vehicle from rolling 2 No gear is engaged 3 Regard the window with infos and instructions NOTICE Short circuit and voltage peaks when connecting the DT VCI Danger of destruction of automotive electronics Switch off ignition before connecting the DT VCI to the vehicle 2 Insert the DT VCI into the vehicle s diagnostic connector Both LEDs of the DT VCI flash The DT...

Page 78: ...g Vehicles from the Car History NOTE Diagnostic results automatically stored here can be retrieved only if the function Automatic Car History Transfer is set to on under Settings Miscellaneous Car History Proceed as follows to select a vehicle from the Car History 1 Select Vehicle selection in the main menu 2 Select the Car History tab 3 Double click the required vehicle to select The device then ...

Page 79: ...hnical Help Line and request data here Proceed as follows to send a help call to the Hella Gutmann Technical Help Line 1 Select Vehicle information in the main menu 2 Call up the Car History with 3 Select the requested Car History file with 4 Call up the Help call menu with 5 If necessary open a list under Contact person with and select the required contact person NOTE You need to enter a telephon...

Page 80: ...t the Technical Help Line check box A Hella Gutmann colleague will call you back as soon as possible 10 Continue with 11 Open the virtual keypad under VIN Vehicle Identification Number with 12 Enter the VIN 13 Confirm your entry with 14 Open the selection window under First registration with 15 Open the list under Day with 16 Select the day of the first registration 17 Repeat steps 15 and 16 for M...

Page 81: ...der Contact person with and select the required contact person NOTE You need to enter a telephone number and to tick at least one of the check boxes to be able to continue 6 Open the virtual keypad under Call back number with 7 Enter the required telephone number 8 Confirm your entry with 9 Activate the check box What do you want to do activate the Request data check box 10 Continue with 11 Open t...

Page 82: ...entered Add further data with Delete the data selection with Use to go back one step and change previous entries 28 Continue with A selection window appears Add further symptoms with Delete the symptom selection with Use to go back one step and change previous entries 29 Continue with An info window appears Here you have an overview of the information that has already been entered Use to go back o...

Page 83: ...Freeze frame data Indication of ambient data rpm coolant temperature of the stored fault code Permanent trouble codes Indication of all permanent trouble codes that are emission relevant Delete trouble codes Deletion of all trouble codes from Mode 2 3 7 Oxygen sensor test results Check and evaluation of oxygen sensor function This mode is not supported at CAN bus protocols Result of sporadic syste...

Page 84: ...ds Only if there are enough values saved the signal will be displayed as a curve on the screen 8 1 Oscilloscope Use the oscilloscope for measuring and or depicting the following measured variables Voltage Current Resistance Current measurements are allowed exclusively with the clamp meter from Hella Gutmann Depending on the required measurement different clamps are to be used CAUTION Overvoltage F...

Page 85: ... to the MT 56 8 1 2 2 Measuring Voltage or Resistance CAUTION Overvoltage Fire hazard danger of damage to the device and its surroundings Comply with the max permitted voltage load of the oscilloscope channels Alternating voltage AC max 30 V Direct current voltage DC max 60 V Proceed as follows to measure voltage or resistance 1 Insert the test lead into MT 56 and connect it to the relevant compon...

Page 86: ... Current will be measured 8 1 3 Setting Measuring Ranges The measuring range can be set in three different ways in the device manual The user adjusts the measuring range automatic The measuring range is adjusted automatically once depending on the input signal continuously automatic The measuring range is continuously adjusted to the input signal At the beginning of each measurement you need to se...

Page 87: ...Range 1 Call up Settings with 2 Select Miscellaneous 3 Open the list under Auto Range with 4 Select off Auto Range is deactivated 5 Confirm the selection with The selected measuring range will no longer be continuously adapted automatically The measuring range can now be set manually 8 1 4 Configuring the Trigger The signal pickup is realized in the trigger mode if the time axis in the oscilloscop...

Page 88: ...llows to set the trigger mode while measurement is in progress 1 Call up Settings with 2 Select the Trigger tab 3 Open the list under Trigger mode with 4 Select normal 5 Confirm the selection with The selection will be saved automatically 8 1 4 3 Setting the Trigger Edge Use the trigger edge setting to decide whether the triggering will be done with a positive edge increasing voltage signal or neg...

Page 89: ...rances Proceed as follows to calibrate the signal while measurement is in progress 1 Start the calibration with The signal will be calibrated 2 Go one step back with 8 1 5 2 Measuring Signals Measurement must be completed to be able to measure the signal in the Guided measurement function Here you can measure the signal For this the device defines two measuring points and determines their differen...

Page 90: ...hile measurement is in progress 1 Call up Settings with 2 Select Indication 3 Activate the check box for the requested measured variables A maximum of 8 measured variables can be displayed at the same time 4 Confirm the selection with The corresponding measured values appear in the left part of the screen 8 1 6 2 Activating the Expert Mode Here you can activate expert mode which is used to enable ...

Page 91: ...out If you select Direct current voltage the device indicates the complete input signal 5 Confirm the selection with The signal indication will be adapted 8 1 6 4 Inverting the Signal Here you can invert the signal indication so that all positive signals are indicated negative and all negative signals are indicated positive This can make sense if a signal is displayed incompletely NOTE To modify I...

Page 92: ...as follows to display a recorded measurement 1 Select Measurements in the main menu 2 Open Measured data folder with 3 Select the requested measurement 4 Confirm the selected measurement with The measurement is displayed 5 Select the requested function Start the measurement display with Interrupt the measurement with Stop the measurement with Return to Oscilloscope with The oscilloscope is opened ...

Page 93: ...mponents 9 2 1 Calling Up the Glossary Proceed as follows to call up the glossary 1 Select Applications in the main menu 2 Select Glossary with 3 Select the required tab with the initial letter of the word you are looking for You can also enter the search term directly with 4 Double click to the requested term An explanatory text is displayed 9 3 Calculations Here you can perform the the following...

Page 94: ... with 3 Select the required calculation type 4 Select the required size 5 Open the virtual keypad with 6 Enter the requested value 7 Confirm your entry with 8 Repeat steps 5 to 7 for further entries where necessary The calculation result is displayed under Result 94 ...

Page 95: ...rather single sheet Check the printer configuration Correctly connect the printer cable Exchange the printer cable for testing purpose Select another printer for testing purpose The oscilloscope indicates wrong values Plug the test lead correctly into the MT 56 Remove all cables except the test lead Attach the test lead correctly to the affected components of the vehicle Replace the test lead for ...

Page 96: ...e European Union In compliance with Directive 2012 19 EU of the European Parliament and Council of 4 July 2012 relating to Waste Electrical and Electronic Equipment WEEE and the German national statute governing the distribution return and environmental disposal of electrical and electronic equipment Electrical and Electronic Equipment Act ElektroG of 16 March 2005 we are obliged to take back this...

Page 97: ...echargeable Battery capacity 44 64 Wh 6200 mAh Display Design TFT Resolution 1024 x 768 XGA Size 10 4 Input Touch screen Ambient temperature Recommended 10 35 C Working range 0 40 C Compatibility asanetwork Weight 2200 g incl battery and module Dimensions 310 x 265 x 100 mm H x W x D Type of protection IP20 Interfaces 1x USB device 2 0 max 480 Mbit s 2x USB host 2 0 max 480 Mbit s Bluetooth class ...

Page 98: ... current 200 mA Voltage supply 12 15 V 10 Ambient temperature Recommended 10 35 C Working range 0 45 C Dimensions 110 x 50 x 26 mm H x W x D Type of protection IP20 Data transfer rate max 3 Mbit s Frequency band 2 4 GHz Interfaces Bluetooth class 1 Micro USB Range inside 3 10 m outside max 50 m 98 ...

Page 99: ...0 mA Ambient temperature Recommended 10 35 C Working range 0 40 C Suitable for humid environment No Altitude max 2000 m above mean sea level Relative air humidity approx 10 90 Continuous operation Yes Weight Approx 220 g Dimensions 40 x 110 x 140 mm H x W x D Type of protection IP20 Bandwidth max 100 kHz Sampling rate 1 MSa s Amplitude resolution 12 bit Overload protection max 200 V Measuring chan...

Page 100: ...General Information mega macs 56 Bike Technical data of the mega macs 56 Bike Measured variables Voltage Current external clamp meter Resistance 100 ...

Page 101: ...nce 0 5 MOhm Input coupling DC AC Input voltage 60 V 42 V Peak Range Current Blue clamp CP 700 Measuring range 700 A Current load max 25 mA Green clamp CP 40 Measurable current 10 40 A Current load max 25 mA Resistance Measuring range 10 Ohm 1 MOhm Measurable resistance approx 1 MOhm Horizontal deflection factor Time coefficient 5 ms 200 s Tolerance 100 ppm Trigger Trigger mode automatic standard ...

Page 102: ...TIONS GMBH Am Krebsbach 2 79241 Ihringen GERMANY Phone 49 7668 9900 0 Fax 49 7668 9900 3999 info hella gutmann com www hella gutmann com 2018 HELLA GUTMANN SOLUTIONS GMBH 1 STUECK PIECE S 9XQ 460 990 371 Made in Germany ...

Reviews: