mega macs 56 Bike
8 Measurements
NOTE
The use of the measuring technology menu requires the optionally available measurement
module (MT 56).
Here you can select measured variables and channel. Then you can perform various measurements.
Measurement technology is a digital signal acquisition and output. This means that the voltage signal is detected and
saved within a few microseconds. Only if there are enough values saved, the signal will be displayed as a curve on the
screen.
8.1
Oscilloscope
Use the oscilloscope for measuring and/or depicting the following measured variables:
•
Voltage
•
Current
•
Resistance
Current measurements are allowed exclusively with the clamp meter from Hella Gutmann. Depending on the required
measurement, different clamps are to be used.
CAUTION
Overvoltage
Fire hazard/danger of damage to the device and its surroundings
Comply with the max. permitted voltage load of the oscilloscope channels:
•
Alternating voltage (AC): max. 30 V
•
Direct current voltage (DC): max. 60 V
84