Installation, important notes!
• Avoid excessive heat generation from
below, e.g. from a baking oven wit-
hout cross
-
flow fan.
• The induction hob must not be used
when pyrolysis operation takes place
on built
-
in cookers.
• When installing above a drawer, care
must be taken to ensure that no
sharp objects are stored in the dra-
wer. These could tilt on the underside
of the hob and block the drawer.
Ensure that the cooktop inductors are
adequately ventilated.
• The cooktop must not be installed
above refrigerators, dishwashers,
washing machines or dryers.
• It must be ensured that no flammable,
easily ignitable or heat deformable
objects are placed directly next to or
below the hob due to the risk of fire.
Hob gasket
Wood worktops must be sealed on the
cut surfaces.
Before installation, the enclosed cooktop
gasket must be inserted without gaps.
• It must be prevented that liquids can
penetrate between the edge of the
hob and the worktop or between the
worktop and the wall into any electri-
cal appliances installed underneath.
• If the hob is installed in an uneven
worktop, e.g. with a ceramic or similar
covering (tiles, etc.), the sealing must
be carried out with level compensati-
on of the cooking surface against the
worktop using plastic sealing materi-
als (e.g. Novasil® or Ottoseal® ).
Note:
• If sealing adhesive is used for sealing
and fixing, a later, non
-
destructive
removal of the hob cannot be guaran-
teed.
Worktop cut
-
out
The cut
-
out in the worktop should be
made as accurately as possible with a
good, straight saw blade or a router
The cut surfaces should then be sealed
to prevent moisture from penetrating.
The cut
-
out for the hob is made accord-
ing to the illustrations. The glass
-
ceramic hob surface must be flat and
flush. Tensioning can cause the glass
plate to break. Check the seal of the
cooking surface for a perfect fit and
complete support.
Floor and plinth cut
-
out
Depending on the base height, the cut
-
out in the base plate can vary.
It is recommended to discharge the ex-
haust air through openings in the plinth
front strip.
PREPARATIONS
7. MOUNTING REQUIREMENTS
-
KITCHEN FURNITURE AND WORKTOP
Summary of Contents for NIVEL 8000 ML Series
Page 11: ...DE 11 Draufsicht Vorderansicht 5 ABMESSUNGEN ...
Page 12: ...DE 12 5 ABMESSUNGEN LÜFTEREINHEIT ...
Page 18: ...DE 18 8 BEARBEITUNG ARBEITSPLATTE ...
Page 35: ...EN 35 top view front view 5 DIMENSIONS ...
Page 36: ...EN 36 5 DIMENSIONS FAN UNIT ...
Page 59: ...FR 59 Vue du dessus Vue de face 5 DESSINS TECHNIQUES EN DIMENSIONS ...
Page 60: ...FR 60 5 DIMENSIONS UNITÉ DE VENTILATION ...
Page 83: ...IT 83 Vista dall alto Vista frontale 5 DIMENSIONI DISEGNI TECNICI ...
Page 84: ...IT 84 5 DIMENSIONI UNITÀ VENTILATORE ...
Page 107: ...ES 107 Vista en planta Vista frontal 5 DIMENSIONES ...
Page 108: ...ES 108 5 DIMENSIONES UNIDAD DE VENTILADOR ...
Page 131: ...NL 131 Bovenaanzicht Vooraanzicht 5 AFMETINGEN ...