 Heavy: 

 Location: 

 Moisture: 

 Heat: 

 Ventilation: 

 Level:

 Pipes: 

 Refrigerant circuit: 

This appliance is heavy, take care when moving it. To avoid back or other injury, 

consider a two person lift or mechanical aid when installing it.

The room for installing appliance must be at least 1M

³

per 8g of refrigerant. 

The amount and type of refrigerant in the appliance can be found on the rating plate on
the back of the appliance. 

Install the fridge in an indoor area protected from wind, rain, water spray or 

drips. 

Do not install it next to an oven, grill or other source of high heat.

To ensure proper ventilation, the front of the unit must be completely 

unobstructed. Keep any ventilation openings clear of obstructions. Choose a well 
ventilated area with temperatures above 16

˚

C and below 43

˚

C. 

Do not damage the refrigerant circuit.

         Install the appliance level in order to ensure proper operation.Adjust the feet
to level the appliance.

Make certain that the pipes are not pinched, kinked or damaged during 

installations. Check for leaks after connection.

 Voltage:

 Separate circuit: 

 Power cord: 

 Damaged cord: 

 Electrical work:

Electrical safety 

 Make sure your outlet voltage and circuit frequency correspond to the voltage 

stated on the appliance rating label. Plug the bar fridge into a 220-240V, 50Hz, 3-prong, 
power outlet with a 15A fuse at the mains. The outlet must be properly earthed to the 
ground.

Do not use an adaptor; do not use an extension cord. We recommend 

you connect the bar fridge to a separate circuit serving only this appliance. This provides 
the best performance and prevents overloading the house wiring circuits that could
cause a fire hazard from overheating. Use a power point that cannot easily be turned off 
accidentally.

Do not kink or damage the power cord. Do not leave it exposed or dangling. 

Secure it behind the unit so no one steps on or places anything on the cord or against it.
Never unplug the unit by pulling the cord. Always grip the plug firmly and pull straight out
from the power point.

Do not use a cord that shows cracks or abrasion damage along its length 

or at either end. If the power cord is damaged, it must be replaced by the manufacturer or 
its service agent. Contact the after sales support line to have it replaced.
                       If the installation of this appliance requires any electrical work, make sure
it is carried out by a qualified electrician. 

Summary of Contents for G67BFW15

Page 1: ...G67BFW15 67L Bar Fridge...

Page 2: ...1 Contents Guide to the Appliance 13 7 4 3 2 14 16 18 Caring for the Envir Safety Information and Getting Started Operation Instructions Troubleshooting Care and Maintenance Technical Specifications...

Page 3: ...r 7 Gasket 8 Adjustable legs 9 Evaporator compartment cover 10 Bottle rack 11 Drip Tray Guide to the Appliance m o r f y l t h g i l s y r a v y a m d e s a h c r u p u o y t i n u e h t t n e m e v o...

Page 4: ...ctly could be potentially hazardous on the environment and human health Observe any local regulations regarding the disposal of electrical consumer goods and dispose of it appropriately for recycling...

Page 5: ...cular attention to safety messages that follow this safety alert symbol or the words DANGER WARNING or CAUTON These words are used to alert you to a potential hazard that can seriously injure you and...

Page 6: ...Damaged cord Electrical work Electrical safety Make sure your outlet voltage and circuit frequency correspond to the voltage stated on the appliance rating label Plug the bar fridge into a 220 240V 50...

Page 7: ...l Refer all other servicing to a qualified technician Cleaning and maintenance Disconnect Unplug the bar fridge or disconnect power before cleaning or servicing Failure to do so can result in electric...

Page 8: ...m the right or left side If your setup requires reversal of the door swing follow the instructions on page 9 Installing the bar fridge Before installing your new upright bar fridge read all safety ins...

Page 9: ...between the sides and wall and the space above the top should be at least 25mm Ensure that there is enough spacing to open the door to 160 Before plugging in your new bar fridge let it stand upright...

Page 10: ...an be opened from either the left side as supplied or right side to suit your individual installation requirements If you want to open the door from the right side follow the instructions below WARNIN...

Page 11: ...ove the core cover from left side to right side And then lift the door and place it on a padded surface to prevent it from scratching 6 Remove the screws and bottom hinge Then remove the levelling fee...

Page 12: ...hinge pin Replace both levelling feet Screw 9 Place the door back on Ensure the door is aligned horizontally and vertically so that the seals are closed on all sides before finally tightening the top...

Page 13: ...cover back 13 With the door closed check that the door is aligned horizontally and vertically and that the seals are closed on all sides before finally tightening the bottom hinge Re adjust the levell...

Page 14: ...minutes before restarting the unit If you attempt to restart before this time delay the unit will not start Operation Instructions The tem perature will be affected by Room tem perature how often the...

Page 15: ...e gasket is dirty or bent The shelves racks or crisper are out of position The fridge door will not open If the door has just been opened leave it for a few minutes to allow the air pressure to equali...

Page 16: ...open Something is preventing the door from closing The door gasket is dirty or damaged Make sure to defrost the fridge regularly The compressor runs continuously The temperature is set too cold select...

Page 17: ...leaning the fridge make sure to turn the temperature control to the 0 position unplug the bar fridge and remove the food and shelves Wash the inside surfaces with a warm water and baking soda solution...

Page 18: ...unit and thoroughly clean and dry the interior To prevent odour and mould growth block the door open slightly Moving the bar fridge Remove all food from inside the fridge tape the door shut and secur...

Page 19: ...0mm x 640mm Total gross volume 67L Total storage volume 62L Fresh food compartment storage volume 57 0L Special compartment storage volume 5 0L Climate class T Rated voltage 220 240V Rated Frequency 5...

Page 20: ...M E W Australia Pty Ltd 15 Vaughan Street Essendon Fields VIC 3041 ACN 152 719 036 1300 725 885 customercare gvaproducts com au gvaproducts com au CKGVA B01 G...

Reviews: