5
Installation
•
Heavy:
•
Location:
•
Moisture:
•
Heat:
•
Ventilation:
•
Level:
•
Pipes:
•
Refrigerant circuit:
This appliance is heavy, take care when moving it. To avoid back or other injury,
consider a two person lift or mechanical aid when installing it.
The room for installing appliance must be at least 1M
³
per 8g of refrigerant.
The amount and type of refrigerant in the appliance can be found on the rating plate on
the back of the appliance.
Install the fridge in an indoor area protected from wind, rain, water spray or
drips.
Do not install it next to an oven, grill or other source of high heat.
To ensure proper ventilation, the front of the unit must be completely
unobstructed. Keep any ventilation openings clear of obstructions. Choose a well
ventilated area with temperatures above 16
˚
C and below 43
˚
C.
Do not damage the refrigerant circuit.
Install the appliance level in order to ensure proper operation.Adjust the feet
to level the appliance.
Make certain that the pipes are not pinched, kinked or damaged during
installations. Check for leaks after connection.
•
Voltage:
•
Separate circuit:
•
Power cord:
•
Damaged cord:
•
Electrical work:
Electrical safety
Make sure your outlet voltage and circuit frequency correspond to the voltage
stated on the appliance rating label. Plug the bar fridge into a 220-240V, 50Hz, 3-prong,
power outlet with a 15A fuse at the mains. The outlet must be properly earthed to the
ground.
Do not use an adaptor; do not use an extension cord. We recommend
you connect the bar fridge to a separate circuit serving only this appliance. This provides
the best performance and prevents overloading the house wiring circuits that could
cause a fire hazard from overheating. Use a power point that cannot easily be turned off
accidentally.
Do not kink or damage the power cord. Do not leave it exposed or dangling.
Secure it behind the unit so no one steps on or places anything on the cord or against it.
Never unplug the unit by pulling the cord. Always grip the plug firmly and pull straight out
from the power point.
Do not use a cord that shows cracks or abrasion damage along its length
or at either end. If the power cord is damaged, it must be replaced by the manufacturer or
its service agent. Contact the after sales support line to have it replaced.
If the installation of this appliance requires any electrical work, make sure
it is carried out by a qualified electrician.
Summary of Contents for G67BFW15
Page 1: ...G67BFW15 67L Bar Fridge...