GVS K-BUS
○
R
KNX/EIB
Thermostat
www.video-star.com.cn
marketing@video-star.com.cn
Tel.
:
(
8620
)
39338986
Fax.
:(
8620
)
39338465
25
Figure 4.4.3 Parameter setting interface of “Heating/cooling setpoint”
Parameter “operation mode after reset”
Options
:
comfort
standby
night
Frost/heat protection
Here we can set the work patterns which is after BUS DEVICE RESET or after programming.
There are 4 work patterns in temperature controller including comfort mode, standby mode, night
mode and Frost/Heating protecting mode. Every mode has its corresponding temperature setting.
Comfort mode is applied to the daytime when someone at home. Standby mode is applied to the
daytime when no one at home for saving the energy. Night mode is applied for the night time when
someone at home. Frost/Heating protecting mode is applied for the long time going out in order to
prevent the devices from damaging by the highest or lowest temperature.