K-BUS
KNX/EIB 3.5/5.0/10.1 inch Touch Panel Plus
88
○
R
non-KNX-standard, which is usually suitable for controlling type of self-definition. The message value is
actual temperature value, such as, message of 17
℃
is 17(decimal number).
16
Outdoor temperature
Page x-AC
2byte
C,W,T,U
9.001 temperature
The communication object is used to receive temperature measurement value sent by the outside
temperature sensor on the BUS, as well as displaying outside temperature on the touch panel.
Table 7.3_6“Air conditioner”Communication Object Table
7.3.7 “Background Music”Communication Object
Figure 7.3_7 “Background Music” Communication Object
S/N
Function
Communication Object
Name
Type
attribute
DPT
5
Power on/off
Page x-BgMusic
1bit
C,W,T,U
1.001 switch
The communication
object
is used to send controlling command of background music on/off to the
BUS, to control on/off of background music on/off, as well as receiving status feedback of background
music on/off from the BUS. Message value:
1——On
0——Off
6
Play/Pause
Page x-BgMusic
1bit
C,W,T,U
1.010 start/stop
The communication object is used to play/pause music from background music module, as well as
receiving status feedback. Message value:
1——Play music
0——Pause music
7
Next song/Previous song
Page x-BgMusic
1bit
C,T
1.007 step
The communication object is used to switch songs from the background music module, switching
to last/next song. Message value:
1——Play next song
0——Play last song
8
/Volume-
Page x-BgMusic
1bit
C,T
1.007 step
The communication object is used to adjust volume of background music. Message value:
1——Increase volume
0——Decrease volume
9
Play mode
Page x-BgMusic
1byte
C,T
5.010 counter pluses
The communication mode is used to send controlling message of play mode of the background
mode, different message is pre-set by parameter.
10
Play mode status
Page x-BgMusic
1byte
C,W,T,U
5.010 counter pluses
The communication object is used to receive status feedback message of play mode of