4.4
Using the Sequence Function
APS-1102 Programmable AC/DC Power Source
4-36
4.4.4
Control of sequence operations
The CONTROL item in the SEQUENCE screen is used to control sequence operations.
A sequence can be started only when output is on. Consequently, the sequence control selection box can
be selected only when output is on.
Table 4-11
lists items in the CONTROL selection box.
Table 4-11. Items in CONTROL Selection Box
Selection Box Items
Operation
START
Starts sequence operation. Switches to Run mode.
STOP
Stops sequence operation. Switches to Idle mode.
HOLD
Pauses sequence operation. Switches to Hold mode.
BRAN0
Branches to the step specified by the branch step.
If the branch step is not specified, it is ignored.
BRAN1
The operation steps are described below.
a) When operating from a menu
Operation steps
1.
When output is on, open the SEQUENCE screen and display the CONTROL selection box.
See
“
4.4.2 Sequence settings
”
, for steps for displaying the CONTROL selection box
.
2.
Press the
or
key to move the cursor to the operation to be set.
ENTER
CANCEL
3.
Press the
ENTER
key to perform the selected operation.