6.3
Command Descriptions
APS-1102 Programmable AC/DC Power Source
6-39
IDN?
T
his returns the model name, etc. The response message includes the “manufacturer, model name,
serial number, and firmware version”.
Syntax:
IDN?
Parameters:
None
Query
example:
IDN?
Response format:
<SRD>
Response example:
“GW Instek , APS-1102, 000001, Ver1.00”
OPC
When all operations
※
have been completed, this sets the standard event register OPC bit (BIT0).
OPC? returns 1 when all operations have been completed. However, the standard event register
OPC bit is not cleared to zero when
OPC? is executed.
Syntax:
OPC
Parameters:
None
Command
example:
OPC
Query
example:
OPC?
Response format:
<NR1>
Response
example: 1
RCL
This recalls status information stored to memory by
SAV. The selection range for the recall
memory is 1 to 30. However, recall is disabled when output is on. ([1, “Invalid with output on”]
error occurs.)
Syntax:
RCL <NR1>
Parameters:
1 to 30
Command
example:
RCL 1
Response format:
None
Response example:
None