9.7 Arbitrary Waveform Memory
The contents of arbitrary waveform memory are retained by battery backup.
a) Number of waveform memories
16
b) Waveform length
4096 words
c) Waveform data
15 bits
Note
: Arbitrary waveform memory cannot be written to
from the panel screen.
The USB interface is used for writing.
9.8 Setting Memory
Various settings are retained in memory with battery backup, and the settings when the power source was
last turned off are restored at power-on. Among these various settings, the basic settings (output mode,
output range, DC settings, AC settings, output current limiter, and setting range limits) can be stored in
store/recall memory No. 1 to No. 30. These stored settings can be recalled.
The recall operation for store/recall memory can be executed only when the output is off.
9.9 Protection Functions
a) Abnormal output
When an output overvoltage or output overcurrent is
detected, the output will be set to off and the error
message is displayed.
b) Abnormal internal power source
When an internal power source abnormality is
detected, the output will be set to off and all
operations will become disabled (system lock) except
for the power-off operation. (In some cases, output
will be set off but shutdown is not necessary.)
c) Abnormal internal control
When a control abnormality is detected, the output
will be set to off and all operations will become
disabled (system lock) except for the power shutdown
operation. (In some cases, output will be set off but
shutdown is not necessary.)
d) Abnormal internal temperature
When an abnormality is detected, the output will be
set to off.