OVERVIEW 

Overall Specification 

1.

 

Maximum voltage between any terminal and ground:  Refer to the different       
input protection voltage ranges shown on the terminals. 

2.

 

10A terminal: Set (CE) 10A H 240V Fast Type Ceramic Fuse 

φ

6x25mm. 

3.

 

mA terminal: Set (CE) 1 A H 240V Fast Type Ceramic Fuse 

φ

6x25mm.       

4.

 

Operating temperature: 0

˚

C~40

˚

C, 32

˚

F ~104

˚

F.             

Relative Humidity:  0

˚

C ~30

˚

C below ≤75%, 30

˚

C ~40

˚

C below ≤50%. 

Storing temperature:-10

˚

C ~50

˚

C (14

˚

F ~122

˚

F).      

5.

 

Electromagnetism: 
Under 1V/m emission: Best Total Accuracy= Specific Ac  
Measurement 5%, Over 1V/m emission does not have any specific index. 

6.

 

Elevation: 0~2000m. 

7.

 

Internal battery: 9V 6F22 or NEDA 1604 or 006P. 

8.

 

Low Battery: indicated by “

” on the LCD display. 

9.

 

Product size: 72mm×137mm×35mm. 

10.

 

Net Weight: About 200g (battery included). 

11.

 

Safety Standard: 
IEC/EN 61010-1: CATIII 250V, Pollution Degree 2. 

12.

 

Conformance: CE. 

 

Summary of Contents for GDM-350B

Page 1: ...Handheld Digital Multimeter GDM 350B USER MANUAL GW INSTEK PART NO 82DM 350B0M01 ISO 9001 CERTIFIED MANUFACTURER...

Page 2: ...another language without prior written consent The information in this manual was correct at the time of printing However we continue to improve our products and therefore reserve the right to change...

Page 3: ...n 7 The Meter Structure 8 MEASUREMENT OPERATION 9 DC or AC Voltage Measurement 10 DC Current Measurement 12 Resistance Measurement 14 Diode Measurement 16 Continuity Measurement 18 Transistor hFE meas...

Page 4: ...sistance temperature the forward voltage drop of diodes transistors hFE and continuity tests The multi purpose socket is used to measure SMTs as well This operating manual covers information on safety...

Page 5: ...y to see if any parts are missing or damaged Item Description Qty 1 Operating Manual 1 piece 2 Test Leads 1 pair 3 K type Temperature Probe Nichrome Nickel Aluminum Thermocouple 1 piece 4 Multi Purpos...

Page 6: ...ons 2 Inspect the test leads for damaged insulation or exposed metal Before using the meter replace any damaged test leads with test leads of the same model number or of the same electrical specificat...

Page 7: ...ver 60V in DC or 30Vrms in AC special care should be taken 9 Do not use or store the meter in an environment with high temperature and humidity The performance of the meter may deteriorate if dampened...

Page 8: ...anual 6 International Electrical Symbols Battery has insufficient charge Ground Warning Refer to the Operating Manual AC Alternating Current DC Direct Current Double Insulated Conforms to Standard of...

Page 9: ...32 F 104 F Relative Humidity 0 C 30 C below 75 30 C 40 C below 50 Storing temperature 10 C 50 C 14 F 122 F 5 Electromagnetism Under 1V m emission Best Total Accuracy Specific Accuracy Measurement 5 Ov...

Page 10: ...GDM 350B User Manual 8 The Meter Structure see diagram 1 1 LCD Display 2 Power Button 3 Rotary Switch 4 Input Terminals 5 HOLD Button diagram 1...

Page 11: ...t check to see that the 9V battery is charged Turn the rotary switch to a measurement position If the battery charge is low the indicator will be displayed on LCD panel Ensure the input voltage or cur...

Page 12: ...t the red test lead into the V terminal and the black test lead into the COM terminal Connect the test leads to the DUT being measured The measured value shows the true root mean square voltage for st...

Page 13: ...f the circuit impedance is less than or equal to 10k the error is negligible 0 1 or less Warning To avoid damage to the meter please do not attempt to input more than 250V To avoid electrical shock pl...

Page 14: ...gram 3 1 Turn the rotary switch to the A position for current measurement 2 Insert the red test lead into the mA or 10A terminal and the black test lead into the COM terminal Connect the test leads to...

Page 15: ...ent function If the correct range is not known select the highest range and work your way down to a lower range if needed Fuses are located on the mA and 10A current input terminals Never attempt conn...

Page 16: ...4 Diagram 4 1 Turn the rotary switch to the position for resistance measurement 2 Insert the red test lead into the terminal and the black test lead into the COM terminal Connect the test leads to the...

Page 17: ...rements the resistance of the test leads must be deducted from the measured resistance Short the test leads and note the measurement result Deduct this value from the resistance of the DUT Measured Re...

Page 18: ...the red test lead into the terminal and the black test lead into the COM terminal The red test lead is the black test lead is 3 In a circuit a good diode should still produce a forward voltage drop r...

Page 19: ...polarity of the diode is incorrect To ensure the accuracy of the diode measurement disconnect power from the circuit and discharge all high voltage capacitors during the measurement The open circuit...

Page 20: ...GDM 350B User Manual 18 Continuity Measurement see diagram 6 Diagram 6...

Page 21: ...sound but if the resistance between both terminals is 10 it indicates a good connection and the buzzer will sound The resistance measurement is displayed on the LCD Unit Warning To maintain measuremen...

Page 22: ...GDM 350B User Manual 20 Transistor hFE measurement see diagram 7 Diagram 7...

Page 23: ...either PNP or NPN or SMT then connect the transistor to be measured to the corresponding jacks 4 The LCD display shows the hFE reference value The testing requirement basic current 10 A Vce of 2 3V W...

Page 24: ...GDM 350B User Manual 22 Temperature Measurement see diagram 8 Diagram 8...

Page 25: ...30 C you need to buy another type of thermocouple 4 When the LCD displays 1 it indicates that the K type thermocouple is not connected When the C terminal and the COM terminal are shorted the meter wi...

Page 26: ...igits guaranteed for 1 year Operating temperature 23 C 5 C Relative Humidity 75 DC Voltage Range Resolution Accuracy 200mV 0 1mV 0 5 Reading 2 Digits 2000mV 1mV 20V 0 01V 200V 0 1V 250V 1V 0 8 Reading...

Page 27: ...olution Accuracy 200V 0 1V 1 2 Reading 3 Digits 250V 1V Input impedance about 4 5M Frequency 45Hz 400Hz Display effective value of a sine wave average value each measurement is applicable from 5 of ra...

Page 28: ...ts 200mA 0 1mA 1 2 Reading 2 Digits 10A 0 01A 2 Reading 5 Digits Overload Protection mA range F2 fuse 6 25mm F 1A H 240V CE 10A range F1 fuse 6 25mm F 10A H 240V CE Warning When 5A Continuous measurem...

Page 29: ...ACCURACY SPECIFICATIONS 27 Resistance Range Resolution Accuracy 200 0 1 0 8 Reading 5 Digits 2000 1 20k 0 01k 200k 0 1k 2000k 1k 20M 0 01M 1 Reading 5 Digits Overload Protection 250V AC or DC...

Page 30: ...ution Accuracy 40 C 20 C 1 C 8 Reading 5 digits 20 C 0 C 4 digits 0 C 100 C 1 0 Reading 3 digits 100 C 1000 C 2 5 Reading 2 digits Overload Protection 250V DC or AC The enclosed K type thermocouple ca...

Page 31: ...Transistor Function Range Resolution Remark Diode 1mV Display positive voltage decline Transistor hFE 1 Continuity Test Function Range Resolution Remark Continuity Test 1 10 Buzzer beeps continuously...

Page 32: ...the cover General Service and Maintenance Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents If there are any abnormalities in the meter stop using the m...

Page 33: ...rning On the LCD display the battery warning indicator indicates the battery is low and needs to be replaced with a new battery Failure to replace the battery causes the measured result to be unstable...

Page 34: ...iver to remove the screws from the battery cover The old battery can now be removed 3 The fuses can be replaced by using a screwdriver to remove the two screws holding the fuses in place Only replace...

Reviews: