background image

About 3V (for 200Ω  range);

1.  30 ranges for function selection;

2.  Over-range display: "1";

3.  Display count: 19999; 

4.  Fast-acting fuse protection for current ranges: 200mA and 10A;

5.  Full-range overload protection; 

6.  Auto power off;

7.  Temperature range:

         Operating: 0

~ 40

(32

 ~ 104

);

         Storage:  -10

~ 50

(14

 ~ 122

);

8.   Altitude: ≤ 2,000m;

9.  Low Battery Indication: 

“    ”

 displays;

10.  Dimensions: 186×91×39mm;

11.  Weight: About 300g (not including test leads).

Ⅰ.

Introduction

Ⅲ.

Product Features

Ⅳ.

Technical Specifications

       The GDM-452 is a 20000-count handheld digital multimeter 

with remarkably stable and reliable operation. It is mainly 

supported with a dual integral A/D converter based on CMOS technology

and also offers overload protection for all ranges. This model can 

measure DC&AC voltage, DC&AC current, resistance, capacitance, 

diode, transistor, frequency and continuity. 

Ⅱ.

Safety Information

     The GDM-452 is designed and manufactured in compliance with: 

IEC61010-1, CAT

1000V, CAT

600V and CAT

300V overvoltage 

standards.

Warnings

Use the meter as specified in the manual , otherwise the protection 

offered by the multimeter may be impaired.

●  Do not use the multimeter with back cover opened, it may cause 

    electric shock.

●  Set to a proper range for your measurement.

●  Check the test leads for any damaged insulation or broken wires.

●  Insert red and black test leads into proper input terminals and ensure 

    good contact between them.

●  Do not input signal beyond the rated values of the multimeter, 

    otherwise it may cause electric shock or damage to the multimeter.

●  Prohibit switching the range during the voltage or current 

    measurement, for it may cause damage to the multimeter.

●  Please use replacement parts with the same model or similar electrical 

    specifications.

●  To avoid electric shock, Do not apply any voltage above 1000V 

    between COM and grounding.

●  Please take caution when working voltage goes above 60VDC or 

    30VAC RMS.

●  To ensure the accuracy, please replace the batteries as soon as 

     

     appears.

●  Shut off the power timely after the measurements complete. Take out 

    the batteries if not used for a long time.

●  Do not use the multimeter in places exposed to high temperature, high 

    moisture. The performance of the multimeter may be compromised if 

    moisture-affected.

●  To prevent damage to the multimeter or personal injury, do not alter 

    internal wiring randomly.

●  Clean the multimeter casing with slightly damped soft cloth and mild 

    agent. Do not use any abrasives and corrosives.

 International Electrical Symbols

Low Battery Indication

Double Insulated

Conforms to European Union Standards

b digits

DC Voltage

AC Current

Resistance

Capacitance

Frequency

Diode and Continuity

AC Voltage

DC Current

AC RMS

AC RMS

True RMS  v

RMS

Note: please short-circuit the test leads when using 200 Ω range to 

measure, and subtract this shorted value from all subsequent measured 

values so as to obtain accurate reading.

Display approximate value 

of forward voltage drop for 

diode

If resistance≤30Ω, the 

buzzer sounds; Display 

approximate kΩ value.

GDM-452

Effective average value

Reviews: