FUNCTION MENU
139
The Fill Function can be used before or after points
are added to the fast sequence.
Before: Will pre-fill each value within the fill
range when a new step is added.
After: Will post-fill each value within the fill
range.
Value setting
Step
02
Step
4
Step
01
Step
FILL example
Step
03
End_Value
Start_Value
Filled
values
Filled steps
Start_Step
End_Step
Setting
Setting Range
Description
Start_Value
Sets the current or resistance
value for the starting step.
End_Value
Sets the current or resistance
value for the ending step.
Start_Step
0001 - 1000
Sets the starting step number.
End_Step
0001 - 1000
Sets the ending step number.