FUNCTION MENU
155
Results:
Power Source
OPP tripped
Exit
OPP
USB
01/Oct/2018
OPP Test
4.81
V
10.530
A
W
50.61
Fetch Watt: Fetch Volt:
60.76 4.79
50.71 4.82
40.57 4.83
30.40 4.85
Watt:
50.72
0:00:07
50.71 W
Save
TEST
Result
The OPP Test will return the current setting of the
last step when the power supply’s OPP was
tripped.
Power Source
OPP time out
Exit
OPP
USB
01/Oct/2018
OPP Test
4.81
V
10.525
A
W
50.61
Fetch Watt: Fetch Volt:
91.21 4.76
81.01 4.76
70.91 4.77
60.73 4.79
Time Out
50.61
0:00:15
OPP time out will occur if the power supply’s OPP
fails to trigger. This is determined when the
measured voltage is less than Trig V and the
measured watt is greater than End W.