FUNCTION MENU
157
BATT Test Automation
Background
The BATT test function creates an automatic test to
test the discharge of Battery products.
The test will discharge in a fixed mode (CC, CR,
CP) and will end after a defined stop point (stop
voltage, stop time, stop AH) has been detected.
The information about discharge test (discharge
time, battery AH, battery WH) can be finally seen
on the panel.
The PEL-3000(H) also has a user-defined cutoff
setting in the event that the Battery test fails.
The diagram below shows an example of the BATT
Test Automation function:
Example
The test will run in the specified mode with
defined values and will stop when the defined
stop values are reached.
Vin
Current
t
SlewRate
=
0
Setting
CC mode
SlewRate
?
Stop Time
Begin Discharge
Stop AH
Stop Volt
AH