GETTING STARTED
19
IMON Out
I MON OUT
Current monitor BNC terminal:
Output connector used to monitor
the current by outputting a
voltage. An output voltage of 1V
(10V for PEL-3000H) corresponds
to the full scale current for the H
and L ranges. 0.1V (1V for PEL-
3000H) corresponds to the full
scale current in the M range.
VMON Out
V MON OUT
Voltage monitor BNC terminal:
Output connector used to monitor
the voltage by outputting a
voltage. An output voltage of 8V
corresponds to the full scale
voltage.
TRIG OUT
TRIG OUT
Trigger out BNC terminal:
Outputs a pulse signal during
sequence or dynamic operation.
The trigger signal has a 4.5V
output with a pulse width of a
least 2us and an impedance of
500Ω.
LINK/STBY
Indicator
(PEL-3211(H))
LINK
STBY
The LINK and STBY indicators
indicate when the booster pack is
properly connected and when the
power has been turned on,
respectively.
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...