PEL-3000(H) User Manual
236
*4 When the input voltage is varied from 1.5V(5V) to 150V(800V) at a current of
rated power/150V(800V)
*5 Measurement frequency bandwidth: 10Hz to 1MHz
*6 Measurement frequency bandwidth: 10Hz to 20MHz
*7 At measurement current of 100A
CR Mode
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
Operating Range
*1
H Range
23.3336S-400µS
(42.857m
Ω
-2.5k
Ω
)
/(H)1.75S~30µS
(571m
Ω
~33.3k
Ω
)
46.6672S-800µS
(21.428m
Ω
-1.25k
Ω
)
/(H)3.5S~60µS
(285m
Ω
~16.6k
Ω
)
140.0016S-2.4mS
(7.1427m
Ω
-416.6667
Ω
)
/(H)10.5S~200µS
(95.2m
Ω
~5k
Ω
)
M Range
2.33336S-40µS
(428.566m
Ω
-25k
Ω
)
/(H)175mS~3µS
(5.71
Ω
~333M
Ω
)
4.6667S-80µS
(214.28m
Ω
-12.5k
Ω
)
/(H)35mS~6µS
(2.85m
Ω
~166k
Ω
)
14.0001S-242.4µS
(71.427m
Ω
-
4.16667k
Ω
)
/(H)1.05S~20µS
(952m
Ω
~50k
Ω
)
L Range
0.233336S-4µS
(4.28566
Ω
-250k
Ω
)
/(H)17.5mS~0.3µS
(57.1
Ω
~3.33M
Ω
)
0.46667S-8µS
(2.1428
Ω
-125k
Ω
)
/(H)35mS~0.6µS
(28.5
Ω
~1.66k
Ω
)
1.40001S-24.24µS
(714.27m
Ω
-41.6667k
Ω
)
/(H)105mS~2µS
(9.52
Ω
~500k
Ω
)
Setting Range
H Range
24.5S-0S
(40.8163 m
Ω
-OPEN)
/(H) 1.75S~30uS
(571m
Ω
~33.3k
Ω
)
49.0S-0 S
(20.408 m
Ω
-OPEN)
/(H) 3.5S~60uS
(285m
Ω
~16.6k
Ω
)
147.000S-0S
(6.8027 m
Ω
-OPEN)
/(H) 10.5S~180uS
(95.2m
Ω
~5.55k
Ω
)
M Range
2.45S-0S
(408.1633m
Ω
-
OPEN)/(H)
175mS~3uS
(5.71
Ω
~333k
Ω
)
4.90S-0S
(204.08m
Ω
-OPEN)
/(H) 350mS~6uS
(2.85mv
Ω
~166k
Ω
)
14.70000S-0S
(68.0272m
Ω
-OPEN)
/(H) 1.05S~18uS
(952m
Ω
~55.5k
Ω
)
L Range
0.245S-0S
(4.08163
Ω
-OPEN)
/(H) 17.5mS~0.3uS
(57.1
Ω
~3.33M
Ω
)
0.490S-0S
(2.0408
Ω
-OPEN)
/(H) 35mS~0.6uS
(28.5
Ω
~1.66M
Ω
)
1.4000S-0S
(680.2721m
Ω
-
OPEN)/(H)
105mS~1.8uS
(9.52
Ω
~555k
Ω
)
Resolution
H Range
400µS(30µS)
800µS(60µS)
2.4mS(180µS)
M Range
40µS(3µS)
80µS(6µS)
240µS(18µS)
L Range
4µS(0.3µS)
8µS(0.6µS)
24µS(1.8µS)
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...