OPERATION
65
Basic Configuration
The basic configuration settings are the common configuration
settings that are used for each operating mode. After selecting a
basic operating mode (CC, CR, CV or CP mode), the slew rate,
switching function, response rate and other common parameters
should be configured.
Select the Switching Function
Description
The PEL-3000(H) has two switching function, static
and dynamic. The switching function allows the
PEL-3000(H) to switch between two preset levels.
Static mode can only switch between the two levels
manually, while Dynamic mode switches between
each level automatically based on a timer.
Static mode: A Value, B Value
Dynamic mode: Level1, Level2
When the unit is set to static mode, only one value
(A Value or B Value) can be active at a time. The
active value is shown in the Operation Status
Panel.
Function
Static
Configure
0.00
W
LOAD
RS232
A Value
Fine
W
W
Active
setting
When the unit is set to dynamic mode, the unit will
switch between Level1 and Level2 based on the
Timer1 and Timer2 parameters, shown below.
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...