FUNCTION MENU
143
Go to Timing Edit for Fast Sequences to edit the
sequence. Page 140.
Go to Running a Fast Sequence to run the fast
sequence. Page 143.
Running a Fast Sequence
Description
Unlike a normal static or dynamic load, a Fast
Sequence load is turned on by pressing the Shift
and Load keys.
Operation
1.
Press
FUNC
>
Fast
Sequence[F3].
2.
Turn fast sequence mode on by setting
F. Seq.[F1]
to
On
.
FSEQ
will appear at the top of the display when
F. Seq.
is On.
3.
Turn the load on by pressing
Shift
Load
On/
Off
.
The
Load
On/
Off
key will turn orange when the
load is “on”.
The load can be turned off again by pressing
the
Load
On/
Off
key.
The fast sequence/chain starts immediately.
The
FSEQ
icon turns orange when the load is
turned on.
4.
When a fast sequence is running, the screen
displays which step and loop is currently
active.
“Sequence Complete”
will be shown on the
display at the end of the sequence.
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...