OPERATION
53
Basic Operation
The PEL-3000(H) supports 7 main operating modes:
CC, CC+CV;
CR, CR+CV;
CV;
CP, CP+CV
CC Mode
Description
In Constant Current Mode the load units will sink
the amount of current programmed. Regardless of
the voltage, the current will stay the same. For
more details on CC mode, please see the Appendix
on page 222.
Warning
If you change the mode or the range when the load is
already on, the load will be turned off automatically.
Operation
1.
Make sure the load is off.
2.
Press
Main
.
3.
Select CC mode with the
Mode[F1]
soft-key.
4.
Select the current range with the
I Range[F2]
soft-key.
Range:
High, Middle, Low
5.
Select the voltage range with the
V Range[F3]
soft-key.
Range:
High, Low
Summary of Contents for PEL-3000 Series