Routine Maintenance
17
ROUTINE MAINTENANCE
The fault indicator will illuminate due to the following reasons:
Shorted or overheated induction heating coil.
Internal damage to the power source.
If the CarDuction is used in a dusty environment, remove the top cover and blow out the
interior of the cabinet once every 2 months
If the CarDuction is routinely transported from site to site, remove the top cover, inspect and/or
tighten all fasteners within the cabinet. Although the Autron has been thoroughly tested for
transit, fasteners can become loose and cause possible damage due to overheating and/or
short circuits.
Listen for the operation of the internal cooling fans and very adequate air flow from the louvers located
on the side of the power source.
Frequently inspect all input power cables, as well as all inductor and foot switch cables for signs of
wear. Do this daily. Replace or repair cables as needed
Disconnect input power and tighten all internal electrical connections every 6 months. Heating and
cooling of the electrical components from normal use will cause electrical connections to loosen over
time and reduce the consistency of the system.
Inspect the integrity of the HF output connector pins and the pins inside the HF connectors of the
heating inductors once per month. Make sure that all contacts are properly aligned and show no signs
of arcing or burns. Replace the inductors immediately if signs of damage are present. Return the
power supply to the factory for service is damage is detected.