Inverter 70
24 HF
Traction batteries
1.
Choose the charging speed according to the capacity (Ah) indicated on your battery.
(Press and hold for 5 seconds)
2.
Select the voltage of the battery (6 / 12 / 24V)
3.
Select the type of battery (liquid or gel):
Liquid: Lead, lead calcium, lead calcium silver,
Gel: Gel batteries, AGM, maintenance free batteries
4.
Connect the clamps: Red clamp on the "+" battery terminal, black clamp on the "-"
battery terminal
5.
Press « Start/Stop »
6.
Before beginning the charge, the Inverter 70.24 HF analyses the battery
voltage/condition and will indicate its status (see the TROUBLESHOOTING section):
If the machine detects that the voltage is different from the one selected, it offers to
modify it. Press OK to confirm the new settings (flashing LED) or push the “Start”
button for 3 seconds if you prefer to keep the current settings (non-flashing LED).
7.
During the charge, the Inverter 70HF display alternates between the current ("I" LED
illuminated: Ampere) and the charge voltage ("U" LED illuminated: Volts).
8.
Once the battery has been charged, if the battery remains connected for more than 48
hours, the Inverter 70HF will automatically restart a charge cycle to compensate for
the automatic discharge of the battery.
9.
Press « Start/Stop » button
10.
Switch « OFF ».
11.
Unplug the power supply cable first and then disconnect the clamps.