Button A on the clamp allows the thickness of the sheets to be welded to be changed remotely. 

Button B on the clamp allows the user to spot weld with the selected parameters. 

 

CAR MANUFACTURER Mode : 

 

The CAR MANUFACTURER mode is optional and is configurable in the setup menu that is activated by pressing the mode 

key for 2 seconds (CAR MANUFACTURER :  ON / OFF). 

 

This mode allows calling, in a nominative manner, a pre-recorded welding spot according to a car manufacturer repair 

specification. Select the CAR MANUFACTURER in the left column, then by pressing the (+) key the spots list is displayed on 

the right column. Select the requested welding spot (highlighted); the machine is ready to weld. 

 

 

 

 

 

User programmed welding spots can be recalled by selecting USER in the list of car manufacturers. The welding spots can be 

programmed using the welding spot programming module in the GYSPOT software. 

 

AUTO Mode : 

 

The AUTO mode is optional and is configurable in the setup menu that is activated by pressing the mode key for 2 seconds 

(AUTO MODE :  ON / OFF). 

 

This mode can be used with the C1, C2, C3, C4, C5, C6, C7, C9 arms. It cannot be used with the C8, C10 and C11 arms, for 

which the error message « ARM NOT COMPATIBLE » will be displayed if they are selected. 

 

This mode allows welding steel sheets without specifying any parameter on the screen of the machine. The machine 

determines the adapted welding parameters. 

 

 

 

 

 

In order to use this mode, a calibration should be first performed by closing the clamp without any  steel between the 

electrodes. Press the « Close clamp / weld » button. The message « Close clamp without steel » appears on the screen. 

Press the button again to perform the calibration. Once the calibration has been performed, the machine displays all the 

parameters to zero, and is ready to weld. Close the clamp on the area to weld and weld automatically, without entering any 

parameter inside the machine. Every 30 welding spots, a new calibration will be requested. 

 

ENERGY Mode : 

 

The  ENERGY  mode is optional and is configurable in the setup menu that is activated by pressing the mode key for 2 

seconds (ENERGY MODE :  ON / OFF). 

 

This mode allows controlling the energy transferred during the welding spot.  This mode is not designed for the repair, but 

is rather meant to be used by car manufacturers and independent control labs. 

 

In order to use this mode, a calibration should be first performed by closing the clamp without any steel sheets between the 

electrodes. Press the « Close clamp / weld » button. The message « Close clamp (without steel) » appears on the screen. 

Press the button again to perform the calibration. Once the calibration has been performed, the machine displays the last 

parameters selected for welding current and energy. 

 

Summary of Contents for Gyspot BP.LC-S7-230V

Page 1: ...oftware 18 21 5 USE AND MAINTENANCE PRECAUTIONS 22 User training 22 Preparation of the parts to assemble 22 Single sided gun welding 22 Level and efficiency of the cooling liquid 22 Cleaning the pneum...

Page 2: ...wet areas or on a wet floor 6 Do not weld with worn out cables Make sure that there is no isolation defect nor stripped cables nor loose connections and that there is no cooling liquid leaks 7 Before...

Page 3: ...X clamp for BP LCX C clamp for BP LC or BP LCX SD card reader Display board for communication with the user Over opening of the clamp Close the clamp and weld A button Remote control to choose the me...

Page 4: ...in order to avoid voltage drops which can generate bad welding spots you must never have overloaded electrical lines nor supply cable diameters which cross section are not large enough Also the mains...

Page 5: ...ecommendations regarding CS330 cooling liquid In case of contact with the eyes rinse thoroughly with plenty of water immediately after contact remove contact lenses first if worn Seek medical help if...

Page 6: ...down keys in the circle allow to select the parameter to modify sheet thickness type of steel arm used The and keys allow to modify the parameter Save user welding parameters The save key allows to sa...

Page 7: ...nd CAR MANUFACTURER modes are available on GYSPOT S7 models only The AUTO mode allows welding without entering any parameter inside the machine This mode may be used on all welding spots identified as...

Page 8: ...electrodes and positioning of the caps Press for 2 seconds to revert back to standard mode STANDARD mode This is the default mode when the machine starts Quick and easy spot welding by selection of th...

Page 9: ...e or decrease the value The highlight allows to select the parameter to modify The parameters to change in this mode are the thickness of each sheet to be welded 0 6 0 8 1 0 1 2 1 5 1 8 2 0 2 5 3 0 th...

Page 10: ...elding steel sheets without specifying any parameter on the screen of the machine The machine determines the adapted welding parameters In order to use this mode a calibration should be first performe...

Page 11: ...ers to modify sheet thickness type of steel arm used The and keys allow modification of each parameter Button A on the clamp remotely adjusts the thickness of the sheets to be welded Button B on the c...

Page 12: ...19 35 corresponds to UHSS steels Re 36 99 corresponds to boron steel Sheet thickness 0 6 0 8 1 0 1 2 1 5 1 8 2 0 2 5 3 0 Type of arm used The up and down button or scrolls through the parameters to mo...

Page 13: ...it is therefore impossible to select higher values for these parameters Set the generator by selecting the thickness of the sheet metal with the key and It is possible to modify the parameters time an...

Page 14: ...lay the message overheating Low battery clock The message Low battery clock appears after switch ON of the machine and alerts the user that the voltage of the battery on the command board is too low T...

Page 15: ...onfigure it in the settings menu which is activated by pushing the mode button for 2 seconds identification mode on off If the identification mode is off enter a file name and activate it to store the...

Page 16: ...inserted in the BP drive instead of the Program SD card The setting screen below is activated by pressing the mode button for 2 seconds When the Identification SD card is inserted and the identificat...

Page 17: ...t with xxx identifier from 001 to 100 In each archive you can save up to maximum 500 welding points The repair order names and users are displayed The page number is indicated top left All the repair...

Page 18: ...h a SD drive The GYSPOT software can be installed from files present on the SD card In the GYSPOT V X XX directory double click on the INSTALL EXE file and follow the instructions to install the softw...

Page 19: ...d automatically before purging 3 4 Entering the report information Each report can include the following information User Car model Repair order Registration number Put into circulation Intervention C...

Page 20: ...a programmed welding spot in the USER file In order to add a welding spot in the USER file select the USER file in the list of files and then click on the button on the right of the table below Enter...

Page 21: ...programmed welding spot select a welding spot in the list and then edit the welding parameters To validated the modifications click on the button To cancel the modifications click on the button 4 4 D...

Page 22: ...ilter located at the back of the machine is cleaned regularly Generator maintenance The maintenance and repair of the generator should only be carried out by a GYS technician Any repair maintenance ma...

Page 23: ...es Unscrew screw and loosen the lever on the side of the clamp Remove the clamp arm Lubricate both a new arm and the support with contact grease ref 050440 Specific Installation for C2 and C8 arms For...

Page 24: ...en not in use clamp stand on either side of the trolley and the gun stand on the arm Failure to follow this precaution may result in serious damage to the user the generator and its tools and there is...

Page 25: ...25 Arms types for the C clamp Spot control Consumables Spotter consumable box Metal Spanner for cap Contact Grease...

Page 26: ...s are face to face then tighten the 2 screws of the circular joint couple 15 Nm Check the cooling liquid level Switch on the unit ATTENTION If the circular joints are not securely tightened as the liq...

Page 27: ...SPOT BP LCX Machine overheats quickly Power cable expands Excessive pressure when changing the X arm C arm missing on the the C clamp C arm cooling pipes are disconnected Assemble the C arm on the C c...

Page 28: ...in respect of the harmonized norm EN 62135 1 Electromagnetic Compatibility Directive EMC 2004 108 CE in respect of the harmonized norm EN62135 2 Machine Directive 2006 42 EC in respect of the harmoni...

Page 29: ...29 9 CIRCUIT DIAGRAM Gyspot BP LC S7 230V...

Page 30: ...30 Gyspot BP LCX S7 230V...

Page 31: ...t BP LCX 185 kg OTHER CHARACTERISTICS Maximum air pressure P1 8 bars Liquid flow rate 2l min Minimum regulated force F min 100 daN Maximum regulated force with C clamp F max 550 daN Maximum regulated...