Replacement of the C arms :
Please read the following instructions carefully.
Incorrectly tightening or setting the C clamp arms can lead to the arm and clamp overheating and causing
damage. Damage caused by incorrect assembly are not covered under the warranty.
Ⓐ
♦
Switch off the machine, or put the machine into
« clamp setting » mode.
♦
Unscrew screw
which holds the arm to the clamp.
Leave it on the arm to not lose it
Ⓑ
♦
Disconnect the cooling liquid pipes.
♦
Unscrew screw
and loosen the lever
on the side of the clamp.
Ⓒ
♦
Remove the clamp arm.
♦
Lubricate both a new arm and the support with contact
grease (ref.050440).
Specific Installation for C2 and C8 arms
For these arms, the Stretches will also need to be changed. Unscrew the short stretches with a flat
spanner and remove the injector.
Centre the injector along the axle of the clamp (Caution: beveled side outside) and insert it manually
(1)
Position the long stretches in front and screw it on to the clamp axle (maximum torque 15Nm) (2)
Stretches types:
Short: C1, C3, C4, C5, C6, C7, C9, C10
Long: C2, C8
Long stretches
Long injector
Short injector
Short stretches
①
②
60
°
!