12
Inverter 70
12 HF
CHARGE MODE
Ensure that the correct sequence is followed:
Precaution: Check the electrolyte level and fill if necessary before charging.
1.
Select « CHARGE » mode
2.
Select type of battery (LIQUID or AGM/GEL):
3.
Connect the clamps: red clamp on the "+" battery terminal, and black clamp on the
"-" battery terminal
4.
Press « Start/Stop »
5.
Before beginning the charge the Inverter 70-12 HF will analyse the battery
voltage/condition and will indicate its status (see the TROUBLESHOOTING section).
6.
During the charge, the Inverter 70-12 HF indicates the charge status of the battery
(bar graph) as well as the current (Ah) and charge voltage (Volts).
7.
At the end of the charge :
•
If the « Floating » option is not activated (see page 14), the Inverter 70 HF
indicates « Battery charged ».
•
If the « Floating » option is activated (see page 14, the Inverter 70 HF will display
« Battery charged »
NB : When the charge ends, if the battery remains connected, the Inverter 70HF
starts again, providing, if necessary, a charge cycle to compensate the automatic
discharge of the battery.
8.
Press « Start/Stop »
9.
Switch « OFF ».
10.
Unplug the power supply cable first, then the battery clamps.
POWER SUPPLY MODE/DIAGNOSIS
On a stationary vehicle, the INVERTER 70 HF supplies up to 70A to ensure compensation of the
current used by high-energy consumers (engine fan, window regulator, electronic suspension etc…)
during testing
- 13.5V -
Default
setting
- 12 - 15V - Diag+ function (see Page …. for full instructions for this feature)