16
Inverter 70
12 HF
Timer:
Maximum value : 24 hours (displays eg : 24H)
Minimum value : 00H = no delay set
To set the timer, enter Setting menu, and when 'Timer' is displayed press the Mode Select
button. Use the Battery Type button to scroll through from 00-24H (after 24H the display
will revert to 00H) - Press the Start/Stop button quickly to ok the setting.
Follow the instructions for the « charge » mode.
The display backlight will deactivate and the LEDs will turn off until the beginning of the charge
cycle. The display will show a count-down to the start of the charge
If a battery is not connected, the count-down will continue without being displayed. At the end of
the count the inverter will display "Connect Battery", and no current will be supplied until a
battery is connected. In case of polarity reversal, the Inverter 70HF will terminate the count-
down, restarting when the battery is connected correctly.
Cables Testing:
This mode must be used each time the output cables are changed. To launch the cable check press
the Start/Stop button. The Inverter 70.12 is compatible with 2 x 5m 16mm
2
or 2 x 12m 50 mm
2
cables.
1.
The message « Short circuit the clamps » is displayed.
2.
Put the clamps in short circuit for more than 10 seconds.
When the clamps are in short circuit, the message, « put the clamp in short-circuit »
disappears.
3.
The result is displayed for 10 sec :
d.
« Ok »: cables are in good working condition.
After 10 sec. Inverter 70HF will automatically revert back to the main menu.
e.
« Check cable / Start: calibrate »: The Inverter 70HF offers either to check or calibrate the
cables using the start/stop button. If the user does not launch the calibration operation
within 10 seconds the unit will revert back to the main menu.
« Check cables » : After switching off the charger, clean the contacts then check the
charge cables and change them if necessary. After this is done, restart the « check
cables » cycle.
Start « calibration »: this function enables the Inverter to calibrate the cables connected
to the machine (length and section) to ensure that the current delivered at the clamps is
correct. To calibrate, put the clamps in short-circuit, press Start/Stop, the Inverter 70HF
displays « calibration OK » then goes back to the main menu.
Charge End
After the battery has been charged, 'Floating' mode continues to deliver a current to the battery to
maintain a maximum charge.
This function is initially active. To disable this function go into the settings menu, select "Restart"
and use the battery type selection button to toggle Float/OFF
Restart
The automatic restart function only works in charge mode - it enables an automatic restart for the
charger in the event of unexpected power loss.
This function is initially active. To disable this function, go into the settings menu, select "Restart",
and use the battery type selection button to toggle ON/OFF