background image

14 

 

 

means that the circuit is open and the oil automatically returns to the 

tank (there is no pressure in the circuit).. 

 

  DEACTIVATION 

 

Any equipment that appears damaged in any way, does not operate normally, or has missing parts should be taken out of 
service immediately by removing the power cord from the electrical outlet. Do not use the unit if you notice parts are broken, 

bent or cracked.  

 

  START-UP 

 

The  QUICK  LIFT  must  be  disposed  of  in  accordance  with  the current environmental and disposal guidelines of the 

country in which it is located. 

 

  WARRANTY CONDITIONS 

 

The warranty covers any defect or manufacturing defect for 2 years from the date of purchase (parts and labor). - 

The warranty does not cover incidents due to misuse, fall, disassembly or other damage due to transportation. The 

warranty does not cover normal wear and tear of parts if maintenance is not kept up to date. Only spare parts from 

the manufacturer may be used to repair the QUICK LIFT. 

 

The characteristics of maximum load appear on the labels sticked on the product. The user must not remove, dirty or 

deface these labels. The warranty will be void if these labels are falsified. Contact the retailer or manufacturer to get 

new ones if needed. 

 

In the event of a malfunction, return the unit to your dealer, enclosing: 

-

 

a dated proof of purchase (till receipt, invoice...) 

-

 

a note explaining the malfunction. 

-

 

Copy of "Regular Security Checks"

 

 

 

SPARE PARTS 

 

 

 

 

 

 

 

 

 

 

 

1  Complete lifting frame 
2 Rubber 

pads 

x4 

3 Cylinder 
4  Hydraulic power pack 220V with wired remote control 
5  flexible long hydraulique (X2)  

Summary of Contents for LUXMAIN QUICK LIFT L520E

Page 1: ...8 QUICK LIFT L520E EN Operating and control manual for a lifting platform User manual French version Made in China Yantai Tonghe Precision Industry Co Ltd www ytthjg com Imported by GYS FRANCE www gys...

Page 2: ...th chock 460 mm E Width 315 mm FEATURES Maximum Load 2 500 kg 1250Kg ramp Safety in case of mechanical fall YES 2 positions Electrical installation 220 V AC 50 60Hz Hydraulic tank capacity 4L Noise le...

Page 3: ...ycle Operation of the mechanical safety devices and the emergency stop button Controls automatically return to initial position No damage to the cylinders the power supply cable and the wired remote c...

Page 4: ...EC Certificate of Conformity EN1493 2010 EN50581 2012 Report No 185226910101 NGBEC1802310202 Control body INSPECCO BELGELENDIRME VE GOZETIM HIZMETLERI A S ID number 2459 NINGBI QIAOPU ELECTRIC CO LTd...

Page 5: ...f passenger vehicles It allows the bodybuilder to lift vehicles safely The maximum load of the QUICK LIFT is 2500 kg The QUICK LIFT may only be used by persons who have read and understood the operati...

Page 6: ...start working around or underneath At the end of a work session return the vehicle to the ground to avoid operating the QUICK LIFT with a full load for a long period of time PACKAGING AND UNLOADING Th...

Page 7: ...he conical seat of the connections Step 3 The tank of the hydraulic unit is empty It must be filled with hydraulic oil or automatic transmission fluid before starting operation Approved fluids are gen...

Page 8: ...een removed from its packaging assembled and positioned on the ground perform a no load test to check the QUICK LIFT s general operation There are two positions for locking the height of the QUICK LIF...

Page 9: ...other and therefore in the passage of the locking bars on the blocks This is normal On load the ramps will be synchronized and the offset will be corrected Pressing DN down will lower the ramps until...

Page 10: ...tter to use a front underneath socket rather than a rear socket which will be lighter unless the engine is at the rear of the vehicle If in doubt seek specialist advice Do not lift any loads directly...

Page 11: ...age pick up points manufacturer s recommendation f Press the UP button on the wired control When the vehicle leaves the ground do not stop the deployment of the ramps until the first locking position...

Page 12: ...nly original spare parts must be used Spare parts The recommended maintenance intervals must be adhered to Maintenance table For maintenance work that is not shown or indicated in the operating instru...

Page 13: ...r other debris from entering the hydraulic system The table below shows the anomalies that can be observed when using the QUICK LIFT If the problem is not listed in the table below stop using the tool...

Page 14: ...rranty does not cover incidents due to misuse fall disassembly or other damage due to transportation The warranty does not cover normal wear and tear of parts if maintenance is not kept up to date Onl...

Page 15: ...sent on hydraulic power pack Max load capacity 2500kg present on the 2 ramps Up UP and down DN signal present Operating instructions original present Tightening of nuts on all axes Condition of hydrau...

Page 16: ...ion of the rubber chocks and 4x4 option Condition of the power cord of the hydraulic power pack General condition of the hydraulic power pack Functional test of the lifting platform with vehicle Contr...

Page 17: ...17...

Page 18: ...18 Importer France GYS FRANCE 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...

Reviews: