background image

 

 

your safety, please read these operating instructions carefully before first use and keep them in a safe place for future 
reference.

 

BACKGROUND INFORMATION 

 

These operating instructions contain important information for installation in order to ensure proper commissioning 

and operational safety of the QUICK LIFT. Complying with the documentation reduces risks and extends the life of the 

product. This manual contains a form to certify regular security checks. Use the "Regular Security Check" form to 
archive the checks. (It is advisable to make a copy of the form before filling it in for the first time.) 

 

Installation and control:

 

Safety work and safety checks are reserved exclusively for specially trained persons. These persons are referred to in 

this documentation as experts and/or authorised persons. 

 

LIABILITY LIMITATIONS 

 

The QUICK LIFT is a manually operated mobile hydraulic lift designed in compliance with standards. All data and 
advice given in these instructions for use have been collected taking into account these applicable standards and 

regulations as well as our extensive knowledge and experience. 

 

The manufacturer cannot be held responsible in case of material and physical damage that could lead to 

death by: 

1- Non-observance of the instructions for use 

2- Improper or dangerous use 

3- Employment of unskilled persons 

4- Unauthorized processing on QUICK LIFT 

5- Insufficient maintenance 

 

INTENDED INTENDED USE

 

 

The QUICK LIFT is designed for the repair of passenger vehicles. It allows the bodybuilder to lift vehicles safely. The 

maximum load of the QUICK LIFT is 2500 kg. 

 

The QUICK LIFT may only be used by persons who have read and understood the operating instructions. 

 

A safety perimeter must be defined in which no one must be present during the lifting operation (minimum 2m around 

the vehicle to allow escape if necessary). 

 

The lifting of persons or other objects is not allowed. No one must be inside the vehicle to be lifted. 

 

The QUICK LIFT must be used inside a work room and protected from bad weather (IP 20, wind, rain and negative 

temperature). 

 

The operating temperature range is between 5°C and 60°C maximum. In case of prolonged storage in a place where 

the temperature is below 0°C, allow at least 12 hours before use by storing it in the workplace. 

 

Do not use in excessively humid conditions. 

 

This equipment is delivered with a 16 A CEE7/7 type plug and must only be used on a single-phase 220 V (50 - 60 Hz) 

electrical installation. 

 

Never lift loads on sloping ground (>3°). The floor must be flat and strong enough to prevent the QUICK LIFT from 

sinking under the weight of the load (35kg/cm²). Under no circumstances should the Quick Lift be placed on an 

inspection hatch on the floor. 

 

It is forbidden to use the QUICK LIFT on a boat/vessel (stability problem). 

 

Thoroughly clean the supporting surface of the vehicle and the rubber pads of the QUICK LIFT before each use. 

Remove all grease and oil stains that could cause the vehicle to slip.

 

Work underneath the vehicle during ascent and descent is not permitted. 

 

Vehicles should only be lifted at the lifting points recommended by the car manufacturers.  Make sure that the QUICK 

Summary of Contents for LUXMAIN QUICK LIFT L520E

Page 1: ...8 QUICK LIFT L520E EN Operating and control manual for a lifting platform User manual French version Made in China Yantai Tonghe Precision Industry Co Ltd www ytthjg com Imported by GYS FRANCE www gys...

Page 2: ...th chock 460 mm E Width 315 mm FEATURES Maximum Load 2 500 kg 1250Kg ramp Safety in case of mechanical fall YES 2 positions Electrical installation 220 V AC 50 60Hz Hydraulic tank capacity 4L Noise le...

Page 3: ...ycle Operation of the mechanical safety devices and the emergency stop button Controls automatically return to initial position No damage to the cylinders the power supply cable and the wired remote c...

Page 4: ...EC Certificate of Conformity EN1493 2010 EN50581 2012 Report No 185226910101 NGBEC1802310202 Control body INSPECCO BELGELENDIRME VE GOZETIM HIZMETLERI A S ID number 2459 NINGBI QIAOPU ELECTRIC CO LTd...

Page 5: ...f passenger vehicles It allows the bodybuilder to lift vehicles safely The maximum load of the QUICK LIFT is 2500 kg The QUICK LIFT may only be used by persons who have read and understood the operati...

Page 6: ...start working around or underneath At the end of a work session return the vehicle to the ground to avoid operating the QUICK LIFT with a full load for a long period of time PACKAGING AND UNLOADING Th...

Page 7: ...he conical seat of the connections Step 3 The tank of the hydraulic unit is empty It must be filled with hydraulic oil or automatic transmission fluid before starting operation Approved fluids are gen...

Page 8: ...een removed from its packaging assembled and positioned on the ground perform a no load test to check the QUICK LIFT s general operation There are two positions for locking the height of the QUICK LIF...

Page 9: ...other and therefore in the passage of the locking bars on the blocks This is normal On load the ramps will be synchronized and the offset will be corrected Pressing DN down will lower the ramps until...

Page 10: ...tter to use a front underneath socket rather than a rear socket which will be lighter unless the engine is at the rear of the vehicle If in doubt seek specialist advice Do not lift any loads directly...

Page 11: ...age pick up points manufacturer s recommendation f Press the UP button on the wired control When the vehicle leaves the ground do not stop the deployment of the ramps until the first locking position...

Page 12: ...nly original spare parts must be used Spare parts The recommended maintenance intervals must be adhered to Maintenance table For maintenance work that is not shown or indicated in the operating instru...

Page 13: ...r other debris from entering the hydraulic system The table below shows the anomalies that can be observed when using the QUICK LIFT If the problem is not listed in the table below stop using the tool...

Page 14: ...rranty does not cover incidents due to misuse fall disassembly or other damage due to transportation The warranty does not cover normal wear and tear of parts if maintenance is not kept up to date Onl...

Page 15: ...sent on hydraulic power pack Max load capacity 2500kg present on the 2 ramps Up UP and down DN signal present Operating instructions original present Tightening of nuts on all axes Condition of hydrau...

Page 16: ...ion of the rubber chocks and 4x4 option Condition of the power cord of the hydraulic power pack General condition of the hydraulic power pack Functional test of the lifting platform with vehicle Contr...

Page 17: ...17...

Page 18: ...18 Importer France GYS FRANCE 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...

Reviews: