POWER SUPPLY
• This material is designed to be powered by a 3-phase 400V power supply only (50-60 Hz) with four wires with a neutral one connected to the earth
and fitted with a ≥ 25 A D-rated circuit breaker (or aM type fuse).
The permanent current absorbed (l1p or ILp) displayed in the section «technical specifications» of this manual relates to use at maximum power.
Check that the power supply and its protection (fuse and/or circuit breaker) are compatible with the current needed by the machine. In some
countries, it may be necessary to change the plug to allow the use at maximum settings.
• Power supply recommendations :
In order to limit the voltage drop in the power supply line and to avoid any risk of disconnection of the protection, it is imperative to connect the
equipment to a «dedicated» socket. This plug must be connected to the electrical panel and only power this equipment.
Check the cross-section of the cable reaching the connection socket: 4 x 6 mm². If the power line from the switchboard is longer than 10 m, use a
conductor cross-section of 10 mm². If you are using an extension cable, use a conductor cross-section of 6 mm² (10 mm² if the length of the line +
extension > 10m).
Power supply cable
Plug 400 V / 3 earth
L1
L2
L3
L1
L2
L3
L1 : Phase 1
L2 : Phase 2
L3 : Phase 3
: Earth (Green/Yellow or green)
Neutral (not used)
• The device turns into protection mode if the power supply tension is below or above the 15% or in the case of no phase. To indicate this default,
the screen displays an error code.
• In order to ensure optimal functioning of the equipment, check that the compressed air circuit can supply 8 bar (116 Psi) and then connect the air
supply to the back of the machine. The machine must not be used on an air network with a pressure under 4 bar (58 Psi) or over 10 bar (145 Psi).
CONNECTION TO A GENERATOR
The equipment is not protected against the regular overvoltage waves emitted by the power generator. It is therefore not recommended to connect
them on this type of power supply.
REFILL OF THE COOLING LIQUID TANK
The cooling liquid recommended by GYS must be used:
5 l: ref. 062511 • 10 l : ref. 052246
Summary of Contents for PTI.G
Page 7: ...7 GYSPOT INVERTER PTI G M5 x 12 4 N m 7 8 M8x16 x4 M5x12 x2 20 N m 4 N m...
Page 11: ...11 GYSPOT INVERTER PTI G 12...
Page 17: ...17 GYSPOT INVERTER PTI G FIG 1 FIG 2 3 4 5 1 9 10 11 7 8 6 2 6 7 1 2 3 8 9 5 4...
Page 52: ...118 SAS GYS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex FRANCE...