52
GYSPOT INVERTER PTI.G
EN
Line
no.
Comment
Display left column
Display right
column
Type of defect
In the event of a blocking fault
Page CHECK n°1
1
Name of the product
PTI-400
PASS
No blocking
2
Product serial number
SN xx.xx.xxxxxx.xxxxxx
PASS or FAIL
No blocking
3
Secondary soft version
CONTROL SOFT Vxx.
xx.xx
PASS
No blocking
4
Hard primary version
ALIM HARD 400V
PASS or FAIL
Blocking
Wrong power supply card, contact your dealer.
5
Primary soft version
ALIM SOFT Vx.xx
PASS, FAIL
Blocking
Wrong software version, contact your reseller.
6
Keyboard test
KEYBOARD
PASS or FAIL
No blocking
Make sure that no key on the keypad or trigger is pressed, if
the fault persists contact your dealer.
7
Communication test µ
COMMUNICATION
PASS or FAIL
Blocking
Communication problem between the cards, contact your
retailer.
8
SD card
SD xx.xx.xx.xx.xxxx
PASS or FAIL
No blocking
SD card not present.
9
Voltage phase 1
U12 = xxx V
PASS or FAIL
Blocking
If there is no phase, pressing MODE for 5s accesses the Setup
menu and allows the machine to operate in Showroom mode.
10
Voltage phase 2
U23 = xxx V
PASS or FAIL
Blocking
11
Voltage phase 3
U31 = xxx V
PASS or FAIL
Blocking
12
CAPA voltage
U+HT = xxx V
PASS or FAIL
Blocking
Problem controlling the power electronics, contact your
dealer.
13
Voltage PM IGBT 1 and 2
UPMIGBT12 = xxx V
PASS or FAIL
Blocking
14
Voltage PM IGBT 3 and 4
UPMIGBT34 = xxx V
PASS or FAIL
Blocking
15
IGBT test result 1
IGBT1 = xxx V
PASS or FAIL
Blocking
16
IGBT test result 2
IGBT2 = xxx V
PASS or FAIL
Blocking
17
IGBT test result 3
IGBT3 = xxx V
PASS or FAIL
Blocking
18
IGBT test result 4
IGBT4 = xxx V
PASS or FAIL
Blocking
Page CHECK n°2
1
Name of the product
CONNEXION TRANSFO
PASS or FAIL
Blocking
Check the connection of the power cable from the gripper to
the generator.
2
Test result primary detec-
tion transfo
DATE/TIME
PASS or FAIL
No blocking
3
Date and time
SHOW-ROOM
ON or OFF
No blocking
4
SHOW-ROOM mode
GGUN WELD SW =
x.xx V
PASS
No blocking
5
Welding trigger, gun
trigger and gun tempera-
ture test
GGUN OPEN SW = x.xx V
PASS or FAIL
Blocking
Check the connection of the power diode temperature sensor.
6
Trigger test on diode ope-
ning and temperature
TRANSFO TEMP = x.xx V
ON or OFF
Blocking
Overheating of the power transformer. Allow the machine to
cool down before starting up again.
7
Transformer primary
temperature
THICKNESS SENSOR =
xx.x mm
PASS
No blocking
8
Position sensor
WELDING VOLTAGE =
x.xx V
PASS
No blocking
9
Welding voltage
BACKUP CELL = x.xx V
PASS or FAIL
No blocking
10
Backup battery voltage
AIR PRESSURE = xx.x
bar si PASS
PASS or FAIL
Blocking
Air pressure sensor from the HS network, contact your dealer.
Network pressure
11
Clamp pressure
GUN PRESSURE = xx.x
bar si PASS
PASS or FAIL
Blocking
Air pressure sensor of the HS gripper, contact your dealer.
Gun presence detection
12
Détection présence pistolet
CONNEXION GUN
ON or OFF
No blocking
SPOT COUNT
A spot count tool keeps count of the different spot weld done using the same cap. If there is no
problem during the welding, the following message is displayed.
The count is displayed at the top left corner of the screen. Press the button
for 2 seconds to
reset the count after changing the caps.
Summary of Contents for PTI.G
Page 7: ...7 GYSPOT INVERTER PTI G M5 x 12 4 N m 7 8 M8x16 x4 M5x12 x2 20 N m 4 N m...
Page 11: ...11 GYSPOT INVERTER PTI G 12...
Page 17: ...17 GYSPOT INVERTER PTI G FIG 1 FIG 2 3 4 5 1 9 10 11 7 8 6 2 6 7 1 2 3 8 9 5 4...
Page 52: ...118 SAS GYS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex FRANCE...