Daily Procedures
9.1.1
General Cleaning
1. Remove the spinner flex shaft cover
assembly (1) in preparation to disassemble
the shake mix chamber (9).
SAFETY NOTE:
Removal of the flex shaft
cover disables the spinner motor.
2. Disconnect the syrup lines and
water rinse line from the mix chamber.
3. Remove the mix chamber and set
aside for cleaning.
4. Disconnect the flex-shaft from
the spinner shaft (taking care not to drop
the spinner shaft which will fall out of the
plunger), remove the spinner shaft from the
shake head.
5.
Prepare a container of sanitizing
solution. Sanitizing solution must be mixed
according to manufacturer’s instructions to
yield 100 PPM strength chlorine solution.
(example: Stera-Sheen Green Label). Use
warm water (100-110°F or 37-43°C). Fill the
wash bottle with sanitizing solution.
6. Using a brush and bottle of
sanitizing solution wash down the bottom of
the shake head and plunger, being sure to
clean the plunger spinner shaft hole with a
brush.
7. Using the bottle of sanitizing
solution.
a. rinse down the head, end of the
plunger, and plunger spinner shaft hole
c. spray out the ends of each
syrup line connector. Also spray the end of
the connector for the water line.
d. wash the mix chamber using
a brush to clean the center bore as well as
each of the syrup holes.
e. wash the spinner shaft using a
brush to clean the paddle holes.
f. rinse off the cleaned mix
chamber and spinner shaft with clean
sanitizing solution.
8. Set parts aside to dry.
9. Leave shake mix system dis-
assembled overnight and re-assemble prior
to the next use. See Assembly Section 7.
10. If your location is open 24 hours,
system must be cleaned once a day, we
recommend cleaning steps 1 through 11 in
the morning or other slow period.
Figure 9-1
9.1
Night or Idle Operation
Summary of Contents for Arby's Electro Freeze Compact Series
Page 2: ......
Page 7: ...ELECTRO FREEZE Shake Model CS704 Safety Decal Locations v 1 P N HC165126 2 P N HC165025...
Page 10: ......
Page 30: ...ELECTRO FREEZE Shake Model CS704 185260 20 Figure 7 4 Head Assembly 7 Assembly continued...
Page 53: ......
Page 55: ......
Page 65: ...ELECTRO FREEZE Shake Model CS704 185260 10 Figure 8 Panel View Sheet 1 of 2...
Page 67: ...ELECTRO FREEZE Shake Model CS704 185260 12 Figure 9 Side View Sheet 1 of 2...
Page 71: ...ELECTRO FREEZE Shake Model CS704 185260 16 ELECTRO FREEZE Shake Model CS704 16...