ELECTRO FREEZE Shake Model CS704
185260
34
11.3 Syrup Calibration
NOTE: Time how long it takes to fill
a medium shake and calibrate the
syrup pumps so that 1½ oz. of syrup is
dispensed in that time.
1. Sanitize and prime each syrup line
as described in section 11.2.
2. Select a syrup flavor by pushing
the proper button on the front of the freezer.
Disconnect that mix chamber syrup tube
from the front panel connector by pushing
the metal clip in. Attach the coupling insert
(see figure 11-7) to the fitting by pushing
the mating end into the panel connector unit
it clicks. Place the barb end of the coupling
insert into the beaker as shown in figure 11-
8.
3. Press the syrup prime/calibrate
button for 5 seconds using a stop watch
or second hand. The measure of syrup
dispensed into the beaker should be 1½
oz. If it is not you will have to adjust the
potentiometer.
4, Repeat steps 2 and 3 for other
flavors.
5. Turn the syrup pump switch to
“OFF”.
6. Open the cabinet door to allow
access to the four flavor adjustment
potentiometers located above the mix
pumps. See figure 11-9.
7. Approximate setting for the
adjustment potentiometers is 7.
8. Calibration levels for each flavor of
syrup should be adjusted to 1½ oz.
9. Select the proper potentiometer for
the flavor to be adjusted.
a. If the amount of syrup
dispensed into the beaker is less than 1½
oz. turn the potentiometer of that syrup
line a few degrees
clockwise for MORE
SYRUP
.
b. If the amount of syrup
dispensed into the beaker is more than 1½
oz. turn the potentiometer of that syrup line
a few degrees
counter-clockwise
for LESS
SYRUP.
10. Close the cabinet door. Place the
syrup pump switch in the “ON” position.
Figure 11-9
Potentiometers
Figure 11-7 Coupling Insert
Part No. HC121061
Mating End
Figure 11-8 Calibration Beaker
Part No. HC196109
11. Repeat steps 2 and 3 to check
calibration. If further adjustment is needed
repeat steps 5 through 10.
12. When desired syrup dispense rate
is achieved, remove the coupling insert and
reconnect the mix chamber syrup tube.
Summary of Contents for Arby's Electro Freeze Compact Series
Page 2: ......
Page 7: ...ELECTRO FREEZE Shake Model CS704 Safety Decal Locations v 1 P N HC165126 2 P N HC165025...
Page 10: ......
Page 30: ...ELECTRO FREEZE Shake Model CS704 185260 20 Figure 7 4 Head Assembly 7 Assembly continued...
Page 53: ......
Page 55: ......
Page 65: ...ELECTRO FREEZE Shake Model CS704 185260 10 Figure 8 Panel View Sheet 1 of 2...
Page 67: ...ELECTRO FREEZE Shake Model CS704 185260 12 Figure 9 Side View Sheet 1 of 2...
Page 71: ...ELECTRO FREEZE Shake Model CS704 185260 16 ELECTRO FREEZE Shake Model CS704 16...