ELECTRO FREEZE Shake Model CS704
185260
35
12 Routine Maintenance
Electro Freeze recommends the following
schedule to help maintain your equipment
in like-new operating condition. Take the
time to learn and perform these routine
procedures and receive in return many
years of valuable service from your
freezer. Protect your investment.
DAILY
1. Disassemble, wash, rinse,
sanitize, air dry, reassemble and sanitize
all parts that come into contact with the
mix or product.
CAUTION
To prevent bacteria growth,
remove all O-rings when
cleaning. Failure to do so could
create a health hazard.
2. Clean and sanitize syrup lines
with sanitizing solution.
3. Clean the cylinder and drain tube
with the appropriate brushes.
3. Upon cleaning, inspect and
lubricate all seals and O-rings as
instructed that come into contact with
mix. Replace any O-ring that is worn,
torn, or loose-fitting.
4. Wipe all exterior surfaces of the
freezer to remove any splattered mix.
5. Check overrun and temperature
of the product.
WEEKLY
1. Carefully inspect all parts for
wear including, seals, O-rings, mix
transfer tube and blades.
2. Replace as required.
Replace blades if worn 3/16” or
more.
3. Check the beater tangs and
drive shaft for wear.
A worn coupling will have a nonparallel
shape on the drive opening.
4. Check the air filter and clean
as necessary. After cleaning apply spray
adhesive, p/n HC162548.
GOOD SHAFT
TANG
Summary of Contents for Arby's Electro Freeze Compact Series
Page 2: ......
Page 7: ...ELECTRO FREEZE Shake Model CS704 Safety Decal Locations v 1 P N HC165126 2 P N HC165025...
Page 10: ......
Page 30: ...ELECTRO FREEZE Shake Model CS704 185260 20 Figure 7 4 Head Assembly 7 Assembly continued...
Page 53: ......
Page 55: ......
Page 65: ...ELECTRO FREEZE Shake Model CS704 185260 10 Figure 8 Panel View Sheet 1 of 2...
Page 67: ...ELECTRO FREEZE Shake Model CS704 185260 12 Figure 9 Side View Sheet 1 of 2...
Page 71: ...ELECTRO FREEZE Shake Model CS704 185260 16 ELECTRO FREEZE Shake Model CS704 16...