ELECTRO FREEZE Soft Serve Model GEN-5099
185242
3
2.2 Installation
CAUTION
All materials and
connections must
conform to local
requirements and be
in compliance with the
National Electrical Code.
1. This freezer is designed for indoor
use and must be protected from outdoor
weather conditions.
2. Where codes permit, Electro
Freeze recommends that the freezer be
installed on casters and have flexible
water and electrical connections for
easier service and cleaning.
3.
All models
require a minimum 6
inch (15 cm) clearance on either the side
panels or the rear panel for adequate
ventilation. Freezers designed with top
air discharge require at least 18 inches
(45 cm) above the top panel be free of
obstructions. Anything blocking ventilation
of the freezer (including cone dispensers)
will reduce the efficiency of the freezer.
4.
Water cooled
double models will
require a 1/2” MPT water inlet and water
waste connection. Both water condensers
are tied together so that one water inlet
and one water waste is all that is required.
The connections are found on the bottom
under the compressor mounting area
and are clearly tagged - “Water Inlet” and
“Water Waste”. A manual shut-off valve
should be installed in the water inlet
line at the time of installation. The water
pressure must be between 35-140 psig
(241-965kPa) for proper operation.
5.
Water cooled and air cooled
remote
freezers require at least 12 inches
(30 cm) above the top panel be free of
obstructions. Anything blocking ventilation
of the freezer (including cone dispensers)
will reduce the efficiency of the freezer.
6. Place the freezer in the final location
and level the machine by adjusting
the legs or casters so that the unit
is level side-to-side, and the front is
approximately ¼” lower than the rear,
to allow proper drainage of the freezing
cylinder.
7.
Water Cooled
Do not allow freezer
to be in ambient where air temperature
goes below 0°C (32°F),the freezing
temperature of water.
8.
Water consumption
increases if
temperature of entering water is above
20°C (65°F)
2.3 Electrical Requirements
2. Supply voltage must be within
+ 10% of voltage indicated on the
nameplate. Also, on three-phase
systems, voltage between phases must
be balanced within 2%. (More than a 6
volt difference between any two voltage
measurements at 208-230 volts indicates
a possible imbalance.) Request your local
power company to correct any voltage
problem.
3. An easily accessible main power
disconnect must be provided for all poles
of the wiring to the freezer.
CAUTION
To prevent accidental
electrical shock, a
positive earth ground is
required.
1. Always verify electrical
specifications on the data plate of each
freezer. Data plate specifications will
always supersede the information in this
manual.
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...