ELECTRO FREEZE Soft Serve Model GEN-5099
4
185242
2.4 Electrical Connections
1. Double freezers with two
compressors require one power supply for
each side of the freezer. Each side of the
freezer operates independently.
2. Check the data plate for fuse
size, wire ampacity and electrical
specifications.
3. Refer to the wiring diagram
provided for proper power connections.
4. Electrical connections are made in
the junction box located mid-level behind
the left side panel.
5. Use a flexible connection when
permissible. All materials and connections
must conform to local codes and the
National Electrical Code.
6. For 3 phase freezers, beater shaft
rotation must be clockwise as viewed
from the front of the freezer.
CAUTION
To prevent accidental
electrical shock, a positive
earth ground is required.
WARNING
Warning:
When installing the machine,
insert an all pole disconnect, adequately
sized according to freezer nameplate
marking with electrical contact spacing of
3mm minimum. This should be within sight
of the freezer.