ELECTRO FREEZE Soft Serve Model GEN-5099
185242
35
10.1 Draining Product
(continued)
dispense the cold water. Follow with a
container of warm water and repeat
until the dispensed water is clear.
Drain remaining water from the
cylinders.
11. Turn the beaters and MTS pumps
“OFF”. Close the spigots
12. Prepare 2 gallons (7.5 liters) of
sanitizing solution for each cylinder.
Sanitizing solution must be mixed
according to manufacturer’s
instructions to yield 100PPM available
chlorine solution (example: Stera-
Sheen Green Label). Use warm water
(100° to 110°F or 37° to 43°C).
13. Insert the mix pickup tubes into the
sanitizing solution.
14. Place an empty container under the
dispense heads.
15. Pull the air bleed plugs up until they
touch the bottom of the switch box.
Open the spigots.
16. Turn the MTS pumps “ON”. When
sanitizer flows out the bottom of the
head, close the air bleed plugs and
allow the MTS to pressurize the
cylinders.
17. Press L1 & R1 to turn turn the beaters
“ON” and allow them to agitate for 5
minutes.
IMPORTANT:
Do NOT use the “FREEZE”
position with sanitizer or water in
the cylinder. The freezer will be
damaged.
18. Slowly open the spigots and allow
the MTS to push the sanitizer out of
the cylinders. Leaving the spigots
open, turn the beaters “OFF”. Leave
CAUTION
Make sure the freezer is
depressurized before proceeding.
the MTS pumps “ON” and allow the
pumps to force all remaining sanitizer
from the cylinders. When sanitizer
quits flowing, place the MTS pump
switches to “OFF”
19. Remove the pickup tubes from the
sanitizing solution.
21. Refer to Disassembly and Cleaning
Instructions.
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...