12 Routine Maintenance
(continued)
CAUTION
Make sure the freezer
is depressurized before
proceeding.
a. Remove cover, loosen
swing clamp and open shoe to gain
access to the hose cavity.
b. Remove mix transfer
hose assembly.
c. Lay a towel on the
cabinet base below the MTS.
d. Using the spray bottle
supplied, flush the hose cavity and
roller assembly.
e. Use a brush (supplied)
to clean in between rollers. Flush
with sanitizer.
f. Wipe all surfaces with a
clean dry cloth.
g. Remove and clean
shoe. See figure 11-1.
WEEKLY
1. Carefully inspect all parts
for wear, including seals, O-rings,
mix transfer tubes, and blades.
2. Replace as required.
Replace blades if worn 3/16” or more.
3. Check the shaft tang and
drive coupling for wear.
A worn coupling will have a nonparallel
shape on the drive opening.
Figure 11-1
LEFT SIDE THE SAME EXCEPT MIRRORED
ROLLER SHOE
BRUSH BETWEEN ROLLERS
GRADE LUBRICANT
SHOE PIVOT ARM
KNOB
LUBRICATE WITH FOOD
GRADE LUBRICANT
SWING CLAMP ARM
SHOE SWING CLAMP
O-RING
O-RING
WASHER
LUBRICATE WITH FOOD
PRESSURE RELIEF SPRING
RIGHT SIDE SHOWN
M02082
AS NEEDED
(continued)
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...