ELECTRO FREEZE Soft Serve Model GEN-5099
185242
45
13 Troubleshooting Tables
(continued)
PROBLEM
PROBABLE CAUSE
REMEDY
Poor or slow
product recovery.
1. Dirty or blocked condenser, restricted air
flow – high ambient temperature.
1.
Have condenser cleaned by your
local service company; lower ambient
temperature.
2. Thermostat cut-in point out of adjustment
or malfunctioning.
2.
Contact your Electro Freeze
Distributor for service.
3. Defective condenser fan motor (air
cooled)
3.
Contact your Electro Freeze
Distributor for service.
4. Component or compressor failure.
4.
Contact your Electro Freeze
Distributor for service.
Beater motor
does not operate.
1. Head assembly is not installed.
1. Install head assembly.
2. Magnetic head switch defective.
2.
Contact your Electro Freeze
Distributor for service.
3. Component failure.
3.
Contact your Electro Freeze
Distributor for service.
Compressor
does not operate
or operates
improperly.
1. Trouble in compressor condensing circuit
1.
Contact your Electro Freeze
Distributor for service.
2. Faulty start capacitor, run capacitor or
relay. (Single phase only)
2.
Contact your Electro Freeze
Distributor for service.
3. Faulty contactor
3.
Contact your Electro Freeze
Distributor for service.
4. Disconnected or broken wire in switch or
capacitor relay box.
4.
Contact your Electro Freeze
Distributor for service.
Compressor and
beater motor
operates only
when dispensing.
1. Cylinder thermostat setting too warm or
thermostat defective.
1.
Contact your Electro Freeze
Distributor for service.
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...