ELECTRO FREEZE Soft Serve Model GEN-5099
46
185242
13 Troubleshooting Tables
(continued)
PROBLEM
PROBABLE CAUSE
REMEDY
Cabinet too
cold. (below
35°F [1.7°C])
1. Cabinet setting too low.
1.
Contact your Electro Freeze
Distributor for service.
2. Defective thermostat.
2.
Contact your Electro Freeze
Distributor for service.
3. Cabinet solenoid stuck open
3.
Contact your Electro Freeze
Distributor for service.
4. Cabinet expansion valve set too low.
4.
Contact your Electro Freeze
Distributor for service.
Mix sours in
cabinet.
1. Cabinet thermostat defective, set too
warm or tuned off.
1.
Contact your Electro Freeze
Distributor for service.
2. Cabinet solenoid defective (does not
open).
2.
Contact your Electro Freeze
Distributor for service.
3. Cabinet switch defective.
3.
Contact your Electro Freeze
Distributor for service.
4. Door switch defective.
4.
Contact your Electro Freeze
Distributor for service.
5. Cabinet compressor contactor coil open
(mix sours in night mode only.
5.
Contact your Electro Freeze
Distributor for service.
6. Faulty time delay.
6.
Contact your Electro Freeze
Distributor for service.
7. Suction pressure too low.
7.
Contact your Electro Freeze
Distributor for service.
Compressor and
beater motor do
not operate when
dispensing.
1. Spigot switch(es) defective or out of
adjustment.
1.
Contact your Electro Freeze
Distributor for service.
2. Component failure.
2.
Contact your Electro Freeze
Distributor for service.
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...