ELECTRO FREEZE Soft Serve Model GEN-5099
185242
49
Error Code
Description/Action
Probable Cause
Remedy
Main Comm
The Main P.C. Board
has stopped receiving
messages from the User
Interface
Action: System shut
down completely.
1. Faulty Wire
Connection
2.Programming Issue
3. Defective Board
1. Check Communication cable
between Main P.C. board and U.I.
board. (Contact Electro Freeze
Factory Tech Support)
2. Ensure U.I. Program version
and Main P.C. Program Version are
compatible. (Contact Electro Freeze
Factory Tech Support Software version
compatibility)
3. If the program versions are
compatible, and using the test cable
does not resolve the issue then the
main control board is not functioning
properly and needs to be replaced.
(Contact Electro Freeze Factory Tech
Support)
NO Comm.
The U.I. Board is not re-
ceiving messages from
the main board
Action: System shut
down completely.
1. Faulty Wire
Connection
2.Programming Issue
3. Defective Board
1. Check Communication cable
between Main P.C. board and U.I.
board. (Contact Electro Freeze
Factory Tech Support)
2. Ensure U.I. Program version
and Main P.C. Program Version are
compatible. (Contact Electro Freeze
Factory Tech Support)
3. If the program versions are
compatible, and using the test cable
does not resolve the issue then the
U.I. board is not functioning properly
and needs to be replaced. (Contact
Electro Freeze Factory Tech Support)
14 VQM Error Codes
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...