ELECTRO FREEZE Soft Serve Model GEN-5099
52
185242
Error Code
Description/Action
Probable Cause
Remedy
Cabinet Rfg
(cont.)
Occurs when cabinet
system run time
exceeds 90 minutes
Action: Barrel
refrigeration switches
to night mode, cabinet
refrigeration is turned
off.
6.Faulty Thermistor
7. Compressor Control
Relay not activating
8. Compressor starting
components failure
9. Compressor failure/
reduced capacity
10. Moisture in System
6. Remove thermistor, check in ice
water and compare to thermistor curve
chart. If faulty replace, if thermistor
tests o.k. check wire harness
connections. If all connections are
sound possibility of control board
issue. (Contact Electro Freeze Factory
Tech Support)
7. Check to see if Relay is receiving
power from Main P.C. board (12VDC),
Ohm relay control coil for proper
resistance. Replace relay as needed.
If no 12VDC is detected Contact
Electro Freeze Factory Tech Support.
8. Check Compressor Starting
components and replace as needed.
9. Check Voltage to the unit to
ensure it is within specification,
Check wire connections to the unit
and compressor, Check compressor
contactor for proper operation,
and possible voltage drop, ohm
compressor windings to check
for a short and proper winding
resistance, check compressor
starting components for failure, allow
compressor protector to reset and
check for proper amp draw.
10. Recover refrigerant, change filter
drier, change compressor oil (Contact
Electro Freeze for proper compressor
oil charge), Evacuate system to a
minimum of 200 microns or less.
Repeat if necessary
Bulb Temp.
Occurs when barrel
thermistor is above or
below temp. limit for 1
minute without change
Action: Affected barrel
is in night time cycle
mode (1min on and
40 min. off), Cabinet
refrigeration remains on
1. Faulty wire
connection
2. Faulty Thermistor
3. Program Issue
1. Locate faulty connection (Wire
rubbed through, cut) and repair as
needed.
2. Remove thermistor, check in ice
water and compare to thermistor curve
chart. If thermistor does not ohm
correctly, replace thermistor.
3. Ensure U.I. Program version
and Main P.C. Program Version are
compatible. (Contact Electro Freeze
Factory Tech Support)
14 VQM Error Codes
(continued)
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...