ELECTRO FREEZE Soft Serve Model GEN-5099
185242
57
Error Code
Description/Action
Probable Cause
Remedy
Low Left Side
(This error only
applies to Dual
Power supply
units)
Displays Low Left Side
if the Power good relay
is not energized, for
the side opposite the
controller.
Action: Left side of unit
is off, and the right side
is operational
1. Main power to left
side is off
2. Power good relay has
failed
3. Faulty wire
connection to power
good relay.
4. Control board issue.
1. Check to see if main circuit breaker
is tripped or unit’s main power cord is
not installed properly.
2. Check coil on power good relay with
ohm meter. If open electrically replace
relay.
3. Check high voltage wire
connections to power good relay.
Check low voltage connections going
from relay to main control board.
Check continuity through relay
contacts to ensure proper operation.
Repair any connections as needed.
4. Contact Electro Freeze Technical
Support
Pump HI PSI
Displays Pump Hi PSI
if the pump pressure is
greater than 40 PSI for
10 seconds while pump
is on.
Action: Affected pump is
turned off
Note: If unit trips this
error and Pressure
relief has not opened,
check to ensure relief is
functioning properly.
1. Pump control relay
is stuck closed causing
pump motor to stay
energized.
2. Faulty Pressure
transducer/out of
calibration.
3. Faulty Control Board
1. Test to see if coil voltage is
present at pump control relay, If it
is not and pump is still running, the
control relay is stuck and needs to be
replaced. If coil voltage is present then
control board or Transducer may be
malfunctioning.
2. Attempt to calibrate the Transducer
to 0 psi and re-test unit. If unit
continues to malfunction contact
Electro Freeze Technical Support.
3. Contact Electro Freeze Technical
Support.
Pump Low
PSI
Displays Pump Low psi
if the pump pressure is
lower than 20 PSI while
in freeze mode.
Action: Affected pump is
turned off
1. Pump transfer hose is
worn out.
2. Leaking Pressure
Relief Valve
3. Hose Shoe is not
tight enough causing
pressure to relieve back
through transfer hose.
1. Replace pump transfer hose
(Should be replaced minimally every
30 days)
2. Ensure o-ring is installed properly
on relief piston, and nothing is
restricting the o-ring from seating
on relief body. Check relief spring
for proper tension and replace as
necessary.
3. Ensure Hose shoe is tightened
down as per the operators manual
instructions.
14 VQM Error Codes
(continued)
Summary of Contents for Electro Freeze GENESIS GEN-5099
Page 2: ......
Page 10: ......
Page 18: ...ELECTRO FREEZE Soft Serve Model GEN 5099 8 185242 4 Part Names and Functions...
Page 74: ......
Page 76: ......
Page 88: ...ELECTRO FREEZE Soft Serve Model GEN 5099 12 185242 Figure 11 Side Back View Breakdown...
Page 94: ......
Page 95: ...ELECTRO FREEZE Soft Serve Model GEN 5099 185242 19 O Ring Chart...