Replace worn brushes. Use only Electro Freeze original
or authorized replacement parts. See Accessories parts
list in Part II of this Manual to order new brushes.
8.3.1 Cleaning and Lubricating MTS Assembly Shoe
Figure 8-12
NOTE:
Clean the shoe weekly or when
necessary.
Do not interchange the shoe
with any other MTS shoes.
Follow these directions for each MTS
shoe:
1. Remove the O-rings and slide the
shoe off of the pivot arm and the swing
clamp off of the clamp arm. See figure
7-12.
2. Carry to the sink, wash in mild
detergent with the brush provided and dry
thoroughly.
3. Brush in between rollers. Flush
clean with water bottle.
Important:
Do not let shoe sit in sanitizing
solution or water. Corrosion will occur
in bore.
4. Lubricate the shoe pivot arm and
the swing clamp arm with food grade
lubricant such as Petrol-Gel.
5. Reassemble the shoe and O-ring
on pivot arm.
6. Reassemble the shoe swing
clamp and O-ring on the swing clamp
arm.