ELECTRO FREEZE Soft Serve Model GEN-2080
185240
71
17 Troubleshooting Tables
(continued)
PROBLEM
PROBABLE CAUSE
REMEDY
Compressor will
not start – hums
intermittently
(cycling on
overload)
1. Improperly wired.
1.
Contact your Electro Freeze
Distributor for service.
2. Low line voltage.
2.
Ask power company to increase
voltage to not less than 10% below
dataplate rating or have transformer
installed. Have wire checked for
inadequate wire size.
3. Open start capacitor. (Single phase only)
3.
Contact your Electro Freeze
Distributor for service.
4. High discharge pressure.
4.
See "Discharge pressure too high"
this section.
5. Defective compressor
5.
Contact your Electro Freeze
Distributor for service.
Compressor
starts, but remain
in start windings.
1. Low line voltage.
1.
Ask power company to increase
voltage to not less than 10%
below nameplate rating or install
transformer.
2. Improperly wired.
2.
Contact your Electro Freeze
Distributor for service.
3.
Running capacitor shorted. (Single phase
only).
3.
Contact your Electro Freeze
Distributor for service.
4.
Start capacitor weak. (Single phase
only).
4.
Contact your Electro Freeze
Distributor for service.