Selection Screen
Pulsing Screen
Priming Screen
Only active outputs
are displayed
Pulse Count
Pulse Indicator
Enter
Exit
Enter
Time-out
or Exit
Priming sends a sequence of six (6) pulses to the selected manifold. If you have more than one pumper on a
manifold and you do not want to prime them all, you will need to turn off some pumpers with the shut-off valves
located on the manifold.
Cancel
/
Exit
will abort the priming sequence after the current stroke. There is a thirty
second period before the controller returns to the base display. During that period you may press
Enter
to repeat
the sequence or you can press
Cancel/Exit
to return to the selection screen and select another output.
Priming a Pumper (Pumphead) or Solenoid Pump
J Plus Advanced Start-Up Guide
Page 2
Turning Global Chemical Feed On or Off
Enter
switches to alternate state:
FEED IS ON
to
FEED IS OFF
or
FEED IS OFF
to
FEED IS ON
Cancel
Enter
Exit
Loop until all
active outputs
have been set.
Enter
Enter
Turning Individual Manifold Feed On or Off
Enter
Enter
Exit
Enter
switches to alternate state:
FEED IS ON (FEEDING)
to
FEED IS OFF (PAUSED)
or
FEED IS OFF (PAUSED)
to
FEED IS ON (FEEDING)
Loop until all
active outputs
have been set.
Enter
Exit
Setting The VPS (Flow Volume per Stroke)
The VPS (Volume Per Stroke) will be displayed as either
Gallons per Stroke
or
Liters per Stroke
according to the setting of
the K Factor Unit (See Page 3)
Both decimal places must be entered, even if zero.
Cancel
Enter
Set Value
Enter
If the manifold capacity has been
entered the stroke capacity and
feed ratio at the current setting will
be displayed. Otherwise the line
will show “
Capacity Not Defined
”