Specifications
LT51 User Manual
88
Sine signal generator (transmitter)
Frequency
1 Hz to 2.2 MHz (1 Hz resolution)
Accuracy
5 ppm
1 Hz
Impedance (balanced)
600
, 75
, 50
Level
0.1 dB resolution
200 Hz to 20 kHz
up to 2.2 MHz
600
-50 dBm to +10 dBm
-50 dBm to +5 dBm
50 and 75
-50 dBm to +16 dBm
-50 dBm to +10 dBm
Attenuator
accuracy
As for Level Meter below
Frequency Response
600
: 200 Hz to 20 kHz:
0.25 dB
(ref: 0dBm/10kHz
)
50 & 75
: 2 kHz to 200 kHz:
0.25 dB
50 & 75
: 2.2 MHz:
0.5 dB
SFDR (0dBm, 600
, typ.)
< 50 dBc
Level meter (receiver)
Frequency Range
200 Hz to 2.2 MHz (upto 7 digits)
Accuracy
5 ppm
1 Hz
Level Range(TX-RX mode)
< -120 to +30 dBm (600/75/50
, Term)
auto-ranging or manual range setting
BWs (see Selectivity below)
25 Hz, 1.74 kHz, 3.1 kHz, Psoph (ITU 0.41)
Impedance (balanced)
Terminated: 600
, 75
, 50
Bridged: > 47 k
,
Attenuator
accuracy
+30 dBm to -30 dBm:
0.2 dB
(ref: 0dBm/10kHz/600
)
-30 dBm to -60 dBm:
0.3 dB
less than -60 dBm:
0.5 dB
Frequency Response
600
: 200 Hz to 20 kHz:
0.25 dB
(ref: 0dBm/10kHz
)
600
: 200 kHz:
0.5 dB (TX-RX only)
50 & 75
: 2 kHz to 200 kHz:
0.25 dB
50 & 75
: 2.2 MHz:
0.5 dB
Level Display
absolute (dBm), relative(rdB)
Resolution
0.01 dB
Input Return Loss
> 25 dB, 50
, 200 Hz to 2.2 MHz
Noise Floor
< -130 dBm/Hz
Selectivity
BW
Passband
Transition
Stopband
25 Hz
5 Hz, < 0.5 dB
12 Hz, < 3 dB
50 Hz, > 30 dB
100 Hz, > 50 dB
500 Hz, > 90 dB
1.74 kHz
-
1.85 kHz, < 3 dB
2 kHz, > 50 dB
3.1 kHz
-
2.7 kHz, < 3 dB
2.5 kHz, > 80 dB