Testing VF-PCM Multiplexers
LT51 User Manual
12
Audio Level Setting
1. Make the connections between the Test circuit and the LT51 as in Fig. 3.1.
2. Turn the LT51 ON. [after Reset: Ztx = 600
, Zrtx = HiZ 600
, TX Source =
OFF, TX Freq =10 kHz, Mode = TX-RX (4W)]
3. Press the button, then the [f2] soft-key to set
Input
to ‘Term’. The
LT51 RTX (input) impedance is now 600
terminated.
4. Press the key, followed by the [f1] soft-key to set the frequency
Span
.
Use the knob to set the span to 4.5 kHz.
5. Press the key followed by the [f4] soft-key to set the TX Freq to 1000
Hz, using the Knob or Keypad, and press the button to clear the Dialog
box, or appropriate [fx] soft-key if using keypad.
6. Press the [f2] soft-key to set the TX Level. This will automatically change
TX Source
to ‘SINE’ and output a 0 dBm, 1000 Hz signal from the TXab
outputs.
Set the desired TX level using the Knob or Keypad, and press the
button to clear the Dialog box, or appropriate [fx] soft-key if using keypad.
7. Repeat for different levels at 2W / 4W interfaces.
8. The display will show the received level and frequency over the 4.5 kHz BW
at the LT51 RTXab input terminals. Press (Spectral) or
(Numerical) to toggle between displays of the signal.