E31 +
tolerance
aberration speed
sensor
The measured
speed-value (actual
value) is higher than
the calculated value
(debit-value)
(at least with the
percentage set in
administrator OP12 )
=
E 31
!
INCR flashing
§ $ %
HELP flashing
Error search see E30.
E32 -
tolerance
aberration speed
sensor
The measured
speed-value (actual
value) is lower than
the calculated value
(debit-value)
(at least with the
percentage set in
administrator OP12 )
=
E 32
!
INCR flashing
§ $ %
HELP flashing
Error search see E30.
E41
Error during memory
initialization
“SETUP ERROR“
MCU
or
low or defective
battery
=
E 41
!
type
"
OP03 flashing
§
SETU
$
P E
%
rrOr flashing
Running machine is still working.
N
At MCU5 control electronic (as of manufacturing date 12/2007), this error shows
a defect of the option memory (FRAM). In this case, please contact h/p/cosmos
and request a service technician.
N
Optional setup restores to default factory setting and device type.
N
By pressing the key
c
, the device can still be used, but it is likely that individual
settings and program profiles may not be available any more. Check accuracy of
displayed values of speed and elevation.
N
Press Start and STOP, power off and power on the device.
N
If E41 is still indicated, contact an authorized service technician.
N
MCU electronic or battery may be low or defective.
E 50
Error of
frequency inverter /
motor regulation
At ANALOG control
of frequency inverter
=
E 50
!
FU flashing
§ $ %
HELP flashing
Running machine out of order.
N
Check plug no. S6 at the MCU board.
N
Frequency inverter may be defective.
N
Power supply may be too weak because of an extension cable etc.
N
Check power supply and power cord.
N
Contact authorized service engineer.