trouble shooting
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
© 2013 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 07.02.2013 printed 04.03.2013 page: 133 of 197
E52 Error
of
RS485 cable motor control
Cable defect or bad contact at the
connection MCU/frequency inverter
Only applicable for digital control
(RS485) of MCU5/frequency inverter
=
E 52
!
FU flashing
§ $ %
HELP flashing
The MCU5 control boards always send a reset message every time
the device is switched on. After 10 consecutive time-out failures, the
MCU generates the E52 error-message. This is equivalent to a
missing connection (e.g. cable defect) from MCU5 to frequency-
inverter.
N
Check RS485 plug at the MCU5 control board.
N
Check RS485 plug at the frequency inverter.
N
Check RS485 plug at the opto coupler board.
N
Contact authorized service engineer.
Card Err
01
Error chip card drive
(not all models)
=
CARD
!
OR S
"
TART
Running machine is still functioning (except chip card function).
Chip card protocol active, but no chip card in chip card drive
N
Insert chip card to the chip card drive, or
N
Press Start to run Cardio Mode
Card Err
02
Error chip card drive
(not all models)
=
CARD
!
ERR
"
2
Running machine is still functioning (except chip card function).
Wrong PIN number
N
False chip card in the chip card drive, or
N
Too many PIN retries (wrong PIN configured)
Card Err
03
Error chip card drive
(not all models)
=
CARD
!
ERR
"
3
Running machine is still functioning (except chip card function).
N
Wrong card type
N
no treadmill training session configured
N
Too many training weeks (memory for training sessions is full).
Card Err
04
Error chip card drive
(not all models)
=
CARD
!
ERR
"
4
Running machine is still functioning (except chip card function).
N
Chipcard reader hardware error
N
Unknown chip card malfunction.
N
No card identified.
N
Check chip card.
N
Insert correct chip card.
N
Reprogram chip card.