technical data
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
© 2013 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 07.02.2013 printed 04.03.2013 page: 147 of 197
stratos
®
, mercury
®
, gaitway
®
locomotion
®
med
h/
p/
cosmos st
ra
to
s
h/
p/
cosmos st
ra
to
s l
t
h/
p/
cosmos mercury
h/
p/
cosmos mercury lt
h/
p/
cosmos st
rat
os med
h/
p/
cosmos st
rat
os med lt
h/
p/
cosmos mercury med
h/
p/
cosmos mercury med lt
h/
p/
cosmos Ki
st
le
r Gai
tway I
I F
[a
]
h/
p/
cosmos Ki
st
le
r Gai
tway I
I S
h/
p/
cosmos locomot
ion 150/
50 E med
h/
p/
cosmos locomot
ion 150/
50 DE med
Dimension of running surface
length x width
1500 x 500 mm
Dimension frame
length x width x height
2100 x 800 x 1370 mm
(UserTe 150 mm width)
2200 x 1000 x
1440 mm
seats: + 400mm
Track access height from floor
180 mm
Weight of device
200 kg
220 kg
350 kg
365 kg
Weight load limits to floors
(traffic load to DIN 1055 part 3)
8.2 kN/m²
8.3 kN/m²
9.1 kN/m²
7.0 kN/m²
In case of any further questions related to load limits onto floors, please ask our service department.
Max. permissible user weight
200 kg (deviation on request specially made)
Environmental conditions:
Transport and storage
temperature: –30...+50 °C, humidity: 0...95 % - without condensation
barometric pressure: 700...1060 hPa
Environmental conditions:
Operation
temperature: +10...+40 °C (deviation on request), humidity: 30...70% - without condensation
(up to 95% on request), barometric pressure: 700...1060 hPa
Maximum operating altitude: approx. 10,000 feet (3000m), without pressurization
Pollution degree
Degree 2: Normally only nonconductive pollution. Temporary conductivity caused by condensation is to be expected.
Central lubrication system
manual
Number of stored programmes
6 training profiles / 10 test profiles / 8 user definable profiles
RS232 Digital interface /
serial port
(USB-converter optional)
COM1: standard
COM2: optional
COM3: optional (standard for service)
COM4: optional
COM1, COM2: standard
COM3, COM4 n.a.
Heart rate measurement
POLAR, 1 channel receiver, ECG precisely
POLAR W.I.N.D.
PC software
(not for medical applications)
h/p/cosmos para control
®
included
options: h/p/cosmos para graphics
®
, h/p/cosmos para analysis
®
and h/p/cosmos para motion
®
Reverse belt rotation
option
standard
Safety arch with chest belt
system***
option
Handrails
options: short / long / adjustable handrails, crossbar
adjustable
Arm support
option
not applicable
Additional keyboard
option
standard
* Overload and weak power supply (under voltage) could lead to higher discrepancies concerning the speed display or dripping of the fuse.
** The time of operation of the elevation motor (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse,
but can be used again after short cool down period. Treadmills of the h/p/cosmos saturn series built approx. before January 2007 have a maximum
elevation of 25 %.
*** For maximum stress tests and with oversize running machines (track sizes) a safety facility (e.g. a safety arch with chest belt system) is necessary and
highly recommended. When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can
deviate.
Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & OE.