technical data
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
© 2013 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 07.02.2013 printed 04.03.2013 page: 153 of 197
h/
p/
cosmos venu
s 200/
75
h/
p/
cosmos venu
s 200/
75 r
h/
p/
cosmos venu
s 200/
100
h/
p/
cosmos venu
s 200/
100 r
h/
p/
cosmos sat
urn 250/
75
h/
p/
cosmos sat
urn 250/
75 r
h/
p/
cosmos sat
urn 250/
100
h/
p/
cosmos sat
urn 250/
100 r
h/
p/
cosmos sat
urn 250/
125 r
h/
p/
cosmos sat
urn 300/
75
h/
p/
cosmos sat
urn 300/
75 r
h/
p/
cosmos sat
urn 300/
100
h/
p/
cosmos sat
urn 300/
100 r
h/
p/
cosmos sat
urn 300/
125 r
h/
p/
cosmos sat
urn 450/
300 rs
Dimension of running surface
length x width in mm
2000 x
750
2000 x
1000
2500 x
750
2500 x
1000
2500 x
1250
3000 x
750
3000 x
1000
3000 x
1250
4500 x
3000
Dimension frame
length x width x height
2400 x
1150 x
1380
2400 x
1400 x
1380
2900 x
1150 x
1380
2900 x
1400 x
1380
2900 x
1650 x
1380
3400 x
1150 x
1380
3400 x
1400 x
1380
3400 x
1650 x
1380
on request
dep. on
install.
Track access height from floor
(optional installation in pit)
480 mm
on request
dep. on
install.
Weight of device
850 kg
900 kg
950 kg
1000 kg
1050 kg
1100 kg
1150 kg
1250 kg
on request
dep. on
install.
Weight load limits to floors
(traffic load to DIN 1055 part 3)
9.0 kN/m² 7.5 kN/m² 7.7 kN/m² 6.5 kN/m² 5.6 kN/m² 7.0 kN/m² 5.8 kN/m² 5.1 kN/m² on request
In case of any further questions related to load limits onto floors, please ask our service department.
Max. permissible user weight on
running surface
280 kg
(deviation on request specially made)
Environmental conditions:
Transport and storage
temperature: –30...+50 °C, humidity: 0...95 % - without condensation
barometric pressure: 700...1060 hPa
Environmental conditions:
Operation
temperature: +10...+40 °C (deviation on request), humidity: 30...70% - without condensation
(up to 95% on request), barometric pressure: 700...1060 hPa
Maximum operating altitude: approx. 10,000 feet (3000m), without pressurization
Pollution degree
Degree 2: Normally only nonconductive pollution. Temporary conductivity caused by condensation is to be expected.
Central lubrication system
manual / running machines with [r] have automatic central lubrication system
Number of stored programmes
6 training profiles / 10 test profiles / 8 user defined profiles
RS232 Digital interface / serial
port
COM1: standard; COM2: standard; COM3: n/a (standard for service); COM4: n/a
Heart rate measurement and
heart rate dependent endurance
control (target pulse
programming)
POLAR W.I.N.D. with WearLink
coded transmission
transmission range approx. 10 m
PC software
(not for medical application)
h/p/cosmos para control
®
and h/p/cosmos para graphics
®
included
option: h/p/cosmos para analysis
®
, h/p/cosmos para motion
®
Reverse belt rotation / downhill
standard
Safety arch with chest belt
system***
obligatory option (or alternative fall stop preventive system)
Wheelchair stabilizer
option
Notebook holder and laptop
computer
option
Additional keyboard
option
Additional emergency button
standard
Science port for raw data of
speed signal
option
* Overload and weak power supply (under voltage) could lead to higher discrepancies concerning the speed display or dripping of the fuse.
** The time of operation of the elevation motor (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse,
but can be used again after short cool down period. Treadmills of the h/p/cosmos saturn
®
series built approx. before January 2007 have a maximum
elevation of 25 %.
*** For maximum stress tests and with oversize running machines (track sizes) a safety facility (e.g. a safety arch with chest belt system) is necessary and
highly recommended. When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can
deviate.
Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & OE.